06.April.06
7/28
COMMAND and PARAMETER list
COMMAND PARAMETER
function example
PW
ON
POWER ON/STANDBY change
PWON<CR>
STANDBY
PWSTANDBY<CR>
?
Request PW Status
PW?<CR>
MV
UP
MASTER VOLUME UP/DOWN , direct change to **dB
MVUP<CR>
DOWN
MVDOWN<CR>
**
**:00 to 99 by ASCII , 80=0dB, 99=---(MIN)
MV80<CR>
?
Request MV Status
MV?<CR>
CV
FL UP
CHANNEL VOLUME UP/DOWN , direct change to **dB
CVFL UP<CR>
FL DOWN
---FRONT Lch
CVFL DOWN<CR>
FL **
**:38 to 62 by ASCII , 50=0dB
CVFL 50<CR>
FR UP
CVFR UP<CR>
FR DOWN
---FRONT Rch
CVFR DOWN<CR>
FR **
**:38 to 62 by ASCII , 50=0dB
CVFR 50<CR>
C UP
CVC UP<CR>
C DOWN
---CENTERch
CVC DOWN<CR>
C **
**:38 to 62 by ASCII , 50=0dB
CVC 50<CR>
SW UP
CVSW UP<CR>
SW DOWN
---SUBWOOFERch
CVSW DOWN<CR>
SW **
**:00,38 to 62 by ASCII , 50=0dB,00=OFF
CVSW 50<CR>
SL UP
CVSL UP<CR>
SL DOWN
---SURROUND Lch
CVSL DOWN<CR>
SL **
**:38 to 62 by ASCII , 50=0dB
CVSL 50<CR>
SR UP
CVSR UP<CR>
SR DOWN
---SURROUND Rch
CVSR DOWN<CR>
SR **
**:38 to 62 by ASCII , 50=0dB
CVSR 50<CR>
SBL UP
---SURROUND BACK Lch (SBch 2SP)
CVSBL UP<CR>
SBL DOWN
CVSBL DOWN<CR>
SBL **
**:38 to 62 by ASCII , 50=0dB
CVSBL 50<CR>
SBR UP
---SURROUND BACK Rch (SBch 2SP)
CVSBR UP<CR>
SBR DOWN
CVSBR DOWN<CR>
SBR **
**:38 to 62 by ASCII , 50=0dB
CVSBR 50<CR>
MV , CV
COMMAND
: "*" parameter uses two or three ASCII characters. (see page4 J) section)