06.April.06
9/28
COMMAND PARAMETER
function example
Z2
UP
MULTI ZONE-2 VOLUME UP/DOWN , direct change to **dB
Z2UP<CR>
DOWN
at
AVR-4306
Z2DOWN<CR>
**
**:10 to 99 by ASCII , 80=0dB, 99=---(MIN)
Z280<CR>
ON
MULTI ZONE-2 ON/OFF change at AVR-4306
Z2ON<CR>
OFF
Z2OFF<CR>
?
Request Z2 Status
Z2?<CR>
Z2MU
ON
ZONE2 OUTPUT MUTE ON/OFF change
Z2MUON<CR>
OFF
Z2MUOFF<CR>
?
Request Z2MU Status
Z2MU?<CR>
Z3
PHONO
MULTI ZONE-3 mode set , and select source at AVR-4306
Z3PHONO<CR>
|
---The name of PARAMETER is
|
AUXIPOD
the same as that of the time of SI COMMAND.
Z3AUXIPOD<CR>
SOURCE
MULTI ZONE-3 mode cancel
Z3SOURCE<CR>
UP
MULTI ZONE-3 VOLUME UP/DOWN , direct change to **dB
Z3UP<CR>
DOWN
Z3DOWN<CR>
**
**:10 to 99 by ASCII , 80=0dB, 99=---(MIN)
Z380<CR>
ON
MULTI ZONE-3 ON/OFF change at AVR-4306
Z3ON<CR>
OFF
Z3OFF<CR>
?
Request Z3 Status
Z2?<CR>
Z3MU
ON
ZONE3 OUTPUT MUTE ON/OFF change
Z3MUON<CR>
OFF
Z3MUOFF<CR>
?
Request Z3MU Status
Z3MU?<CR>
SR
PHONO
REC SELECT mode set , and select source
SRPHONO<CR>
|
---The name of PARAMETER is
|
AUXIPOD
the same as that of the time of SI COMMAND.
SRAUXIPOD<CR>
SOURCE
REC SELECT mode cancel
SRSOURCE<CR>
?
Request SR Status
SR?<CR>
Z3
COMMAND
: "*" parameter uses two ASCII characters. (see page4 J) section)