background image

10

4   Assembly and connection

4.1  Connect the pressure reducer to the reusable CO

2

 Soda bottle

•  Place the CO

2

 bottle in the stand.

• 

Turn the control knob all the way to "-" (CO2 supply closed).

•  Check to make sure that the seal in the connection piece of the pressure reducer and the sealing surface of the bottle 

valve are clean.

• 

Hold the pressure reducer straight and screw it on slowly until you feel a slight resistance:

 The pin in the connection 

piece of the pressure reducer is now on the bottle valve. Next, quickly turn

 the pressure reducer further until it is hand-

tight It may hiss a bit. 

[3]

• 

The pressure reducer can be unscrewed at any time – the bottle valve closes automatically. It may also hiss a bit during 

the first turn when unscrewing, so it is best to start unscrewing the pressure reducer with a quick motion.

4.2  Installing the check valve

• 

The check valve should be installed in the hose as close to the aquarium as possible. Make a 

straight cut in the hose 

at the appropriate length.

• 

Push the hoses all the way onto the hose connections and secure with union nuts. 

 

CAUTION: The 

arrow

 on the check valve must point in the flow direction of the CO2, i.e. from the CO2

 source to the 

diffuser! 

[4]

•  Connect hose to pressure reducer and secure with union nut. 

[5]

4.3  Connecting the CO

2

 diffuser

• 

Mount the diffuser vertically in the aquarium for a few hours before use so that the diffuser fills with a little water 

(bubble counter function).

• 

The diffuser can also be connected directly. It will fill with water during operation (in this case there is no bubble 

counter function at first).

•  Moisten the hose connection and attach the CO

2 supply hose.

• 

Fasten the diffuser with the suction cup as low as possible in the aquarium. 

[6]

Your CO

2

 fertilization system is now ready for operation.

5   Setting the CO

2

 quantity (bubble count)

5.1  The right amount of CO

2

For lush plant growth, Dennerle recommends a CO2 content in the aquarium between 

20 and 25 mg/l

CO

2 contents above 30 mg/l are not necessary for healthy plant growth and should be avoided in order to prevent unneces

-

sary stress for fish and other aquarium inhabitants.

The CO

2 content can be determined easily with a 

Dennerle CO

2

 long-term test

 or by measuring the carbonate hardness 

and pH value (see 6).

5.2  Setting the bubble count

One measure for the amount of CO

2 supplied is the bubble count. The required bubble count depends on various factors, 

such as the type of plants, the water flow and the illumination intensity. This is why it is necessary to calculate the amount 

of CO

2 for each aquarium individually.

Rule of thumb for basic setup:

 Start with 

approx. 15 bubbles per minute per 100 l of aquarium water. For example, for a 200 

l aquarium, start with approx. 2 x 15 = 30 bubbles per minute.  

Adjust the CO

2 supply in small steps over several days

 until the desired CO

2

 content has been reached. Please note: The 

more the water surface is moving, the more CO2 is driven out of the aquarium.  

• 

Close the needle valve (turn clockwise). CAUTION: Precision thread, only tighten slightly.

• 

Turn the control knob on the pressure reducer in "+" direction until the working pressure manometer shows approx. 

1,5 bar. 

[7]

• 

Open the needle valve until the first bubbles escape from the diffuser.

• 

Set the desired number of bubbles by turning the needle valve.

• 

TIP: A fine adjustment can also be made by slightly increasing or reducing the working pressure in the range of 1 - 2 bar.

•  Please note:

  To  check  the  bubble  count,  the  diffuser  must  have  some  water  in  it.  The  bubble  count  reacts 

to  changes  on  the  pressure  reducer  with  a  time  delay  (the  hose  acts  as  a  pressure  buffer).  Therefore,  ad

-

just the bubble setting in small steps

  and  always 

wait a few minutes until the new setting has stabilised. 

Summary of Contents for Carbo Soda M200

Page 1: ... 15 IT Istruzioni per l uso 21 NL Gebruiksaanwijzing 27 Carbo Soda M200 Druckminderer Carbo Soda Carbo Soda M200 Pressure reducer Carbo Soda Carbo Soda M200 Détendeur CO2 Carbo Soda Carbo Soda M200 Riduttore di pressione Carbo Soda Carbo Soda M200 Drukregelaar Carbo Soda ...

Page 2: ...3 4 5 6 7 1 5 4 2 3 6 1 2 2 4 3 1 ...

Page 3: ...eicher Bauart ersetzt werden Sollten Sie bemerken dass eine Gefahr von den CO2 Druckgaskartuschen ausgeht müssen sie die Filiale in der Sie die Druckgaskartuschen erworben haben darüber informieren Sicherheitsvorschriften allgemein Nur im Innenbereich bei Raumtemperatur verwenden Das Gerät ist nicht dazu bestimmt durch Personen einschließlich Kindern mit eingeschränkten physischen sensori schen od...

Page 4: ...Einstellen der CO2 Menge Blasenzahl 5 1 Die richtige CO2 Menge Dennerle empfiehlt für prächtigen Pflanzenwuchs einen CO2 Gehalt im Aquarium von 20 bis 25 mg l CO2 Gehalte über 30 mg l sind für gesundes Pflanzenwachstum nicht erforderlich und sollten vermieden werden um Fische und andere Aquarienbewohner nicht unnötig zu belasten Der CO2 Gehalt kann auf einfache Weise mit einem Dennerle CO2 Langzei...

Page 5: ...6 5 6 6 6 7 6 8 6 9 7 0 7 1 7 2 7 3 7 4 7 5 2 32 25 20 16 13 10 8 6 5 4 3 3 2 3 48 38 30 24 19 15 12 10 8 6 5 4 3 4 64 51 40 32 25 20 16 13 10 7 6 5 4 5 80 63 50 40 32 25 20 16 13 10 8 6 5 6 96 76 60 48 38 30 24 19 15 12 10 8 6 7 111 89 70 56 44 35 28 22 18 14 11 9 7 8 127 101 80 64 51 40 32 25 20 16 13 10 8 9 143 114 90 72 57 45 36 29 23 18 14 11 9 10 159 126 100 80 63 50 40 32 25 20 16 13 10 11 ...

Page 6: ...fschneiden um eine Beschädigung der Schlauchanschlüsse zu vermeiden 7 5 CO2 Diffusor reinigen Mit warmem Wasser und weichem Schwamm oder weicher Bürste Keine Reinigungsmittel verwenden 8 Was tun wenn Fehlerbehebung Fehler Ursache Behebung An Schraubverbindung von Druckmin derer und CO2 Flasche ist ein leises Zischen zu hören Druckminderer ist schräg oder nicht fest genug aufgeschraubt Dichtung im ...

Page 7: ...haftungsgesetz Garantie Dennerle gewährt dem Käufer eine Garantie von 4 Jahren ab Kaufdatum Die Garantie umfasst Produktions und Materialfehler Verschleißteile sowie Korrosionsschäden am Druckminderer oder Magnetventil durch eingedrungenes Wasser sind von der Garantie ausgenommen In der Garantiezeit erhalten Sie kosten losen Ersatz bzw kostenlose Reparatur defekter Teile Voraussetzung ist ein best...

Page 8: ...8 ...

Page 9: ...e valve can be damaged and CO2 gas can escape Ensure adequate ventilation The CO2 bottle contained in the set can only be replaced by a standard Soda bottle of the same type If you notice that there is a danger from the CO2 pressurized gas cartridge immediately inform the dealer from whom you purchased it General safety regulations For indoor use at room temperature only The device is not intended...

Page 10: ...now ready for operation 5 Setting the CO2 quantity bubble count 5 1 The right amount of CO2 For lush plant growth Dennerle recommends a CO2 content in the aquarium between 20 and 25 mg l CO2 contents above 30 mg l are not necessary for healthy plant growth and should be avoided in order to prevent unneces sary stress for fish and other aquarium inhabitants The CO2 content can be determined easily ...

Page 11: ... 10 8 6 5 4 3 3 2 3 48 38 30 24 19 15 12 10 8 6 5 4 3 4 64 51 40 32 25 20 16 13 10 7 6 5 4 5 80 63 50 40 32 25 20 16 13 10 8 6 5 6 96 76 60 48 38 30 24 19 15 12 10 8 6 7 111 89 70 56 44 35 28 22 18 14 11 9 7 8 127 101 80 64 51 40 32 25 20 16 13 10 8 9 143 114 90 72 57 45 36 29 23 18 14 11 9 10 159 126 100 80 63 50 40 32 25 20 16 13 10 11 175 139 111 88 70 55 44 35 28 22 18 14 11 12 191 152 121 96 ...

Page 12: ...ducer and CO2 bottle Pressure reducer is screwed on at an angle or not tight enough Seal in pressure reducer is dirty or defective Unscrew the pressure reducer and screw it back on straight Clean the sealing surfaces Replace the seal if necessary No more bubbles on the CO2 diffuser CO2 bottle empty Working pressure too low Needle valve closed Hose connection leaking Replace the CO2 bottle Increase...

Page 13: ... damage to the pressure reducer or magnet valve due to water ingress are excluded from the warranty During the guarantee period Dennerle will replace and or repair any defective parts free of charge provided the device has been used normally in accordance with the instructions During the guarantee period the device may only be opened by Dennerle after sales service otherwise the guarantee will bec...

Page 14: ...14 ...

Page 15: ...uler avec précaution Ne pas lancer Ne pas ouvrir de force Conserver au frais Protéger des températures supérieures à 50 C Ne pas conserver dans les sous sols Ne pas inhaler le CO2 est asphyxiant à concentration élevée En cas d échappement de CO2 bien aérer la pièce Utiliser exclusivement pour l approvisionnement en CO2 d aquariums Prélèvement de CO2 uniquement à l aide du détendeur de pression app...

Page 16: ...res avant utilisation pour qu il puisse se remplir d eau fonction compte bulles Le diffuseur peut également être raccordé directement Il se remplit d eau au fur et à mesure du fonctionnement dans ce cas la fonction compte bulles ne fonctionnera pas immédiatement Humidifiez légèrement le raccord de flexible puis glissez y le flexible d alimentation en CO2 Fixez le diffuseur de plus bas possible dan...

Page 17: ... bulles et ajustez le si nécessaire Par la suite il suffit en général de le contrôler une fois par semaine 6 Teneur en CO2 dans l aquarium La teneur en CO2 la dureté carbonatée KH et le pH ont un certain lien proportionnel entre eux Le pH et la dureté carbo natée permettent un calcul précis de la teneur en CO2 de l eau Vous trouverez des tests de pH et KH appropriés dans les commerces spécialisés ...

Page 18: ... pendant la durée d utilisation du détendeur En cas de besoin le joint peut être extirpé avec un outil adéquat Veiller à ne pas endommager la surface d étanchéité et le filetage 7 4 Enlever le flexible CO2 Il arrive qu après un temps d utilisation relativement long le flexible CO2 colle fortement au raccord du détendeur et d au tres appareils de CO2 Pour le démonter soulevez le de préférence à l a...

Page 19: ...s Dennerle répond des dommages matériels à d autres biens occasionnés par un défaut du produit ainsi que des dommages corporels ainsi causés conformément à la loi sur la responsabilité du fait des produits Garantie Dennerle offre à l acheteur une garantie de 4 ans à compter de la date d achat La garantie englobe les défauts de production et de matériel Les pièces d usure et les dégâts de corrosion...

Page 20: ...20 ...

Page 21: ...na bombola di ricambio soda disponibile in com mercio dello stesso design Se notate che c è un pericolo dalle cartucce di gas pressurizzato CO2 dovete informare la filiale dove avete acquista to le cartucce di gas pressurizzato Norme di sicurezza generali Solo per uso interno a temperatura ambiente Questo dispositivo non è idoneo all uso da parte di persone bambini compresi con facoltà fisiche sen...

Page 22: ...cquario 6 L impianto di CO2 è ora pronto per l uso 5 Impostazione della quantità di CO2 contabollicine 5 1 La giusta quantità di CO2 Per una crescita delle piante rigogliosa Dennerle consiglia un contenuto di CO2 in acquario da 20 a 25 mg l Perché le piante crescano sane non è necessario un contenuto di CO2 superiore ai 30 mg l anzi va evitato per non sovrac caricare inutilmente i pesci e gli altr...

Page 23: ...O2 desiderato Si dovrebbe impostare tale valore pH tra 0 1 con la relativa regolazione del numero di bollicine Esempio durezza carbonatica 4 d contenuto di CO2 desiderato 20 mg l pH consigliato 6 8 troppa CO2 CO2 giusta CO2 scarsa Valore pH KH 6 3 6 4 6 5 6 6 6 7 6 8 6 9 7 0 7 1 7 2 7 3 7 4 7 5 2 32 25 20 16 13 10 8 6 5 4 3 3 2 3 48 38 30 24 19 15 12 10 8 6 5 4 3 4 64 51 40 32 25 20 16 13 10 7 6 5...

Page 24: ...filettatura 7 4 Rimuovere il tubo per CO2 Dopo un tempo di funzionamento abbastanza lungo il tubo per CO2 può restare attaccato molto saldamente al collegamen to del riduttore di pressione e di altri dispositivi per CO2 Per smontarlo la cosa migliore è utilizzare un piccolo cacciavite per sollevarlo Non tirare con forza né tagliare con un coltello per evitare di danneggiare i collegamenti del tubo...

Page 25: ...nerle risponde dei danni causati ad altre cose da un difetto del prodotto e dei danni alle persone derivanti da tale difetto in base alla legge sulla responsabilità per danni da prodotti difettosi Garanzia Dennerle concede all acquirente una garanzia di 4 anni dalla data di acquisto La garanzia comprende i difetti di produzione e di materiale I pezzi soggetti a usura come i danni al riduttore di p...

Page 26: ...26 ...

Page 27: ... in de handel verkrijgbare vervangingscilinder voor soda van hetzelfde product Indien u vaststelt dat de CO2 drukgaspatronen een gevaar vormen moet u het filiaal waar u de drukgaspatronen hebt gekocht daarvan in kennis stellen Algemene veiligheidsvoorschriften Alleen binnenshuis gebruiken bij kamertemperatuur Het apparaat is niet ontworpen om door personen inclusief kinderen met beperkte fysieke s...

Page 28: ...r goede plantengroei niet wenselijk en zouden vermeden moeten worden om vissen en andere aqaurium bewoners niet onnodig te belasten Het CO2 gehalte kan gemakkelijk worden bepaald met een Dennerle CO2 langetermijntest of door de carbonaathardheid en de pH waarde te meten zie 6 5 2 Instellen van het bellen aantal Een maat voor de hoeveelheid toegevoegde CO2 is het aantal bellen Het benodigde aantal ...

Page 29: ...126 100 80 63 50 40 32 25 20 16 13 10 11 175 139 111 88 70 55 44 35 28 22 18 14 11 12 191 152 121 96 76 60 48 38 30 24 19 15 12 13 207 164 131 104 82 65 52 41 33 26 21 16 13 14 223 177 141 112 89 70 56 44 35 28 22 18 14 CO2 Niveau in mg l 7 Verzorging en onderhoud 7 1 Vervanging van de CO2 Soda herbruikbare fles De drukregelaar kan ten alle tijde van de fles worden afgedraait het flesventiel sluit...

Page 30: ...eekt of vervuild of beschadigt Drukregelaar verwijderen en nog maals recht verbinden Afdichtring schoonmaken of vervan gen Geen bellen meer in de diffusor CO2 Fles leeg Te lage werkdruk Naaldventiel gesloten Slang verbinding lek CO2 Fles omruilen Verhogen van de werkdruk Open naaldventiel Slang verbindingen controleren even tueel vervangen 9 Uitbreiding voor CO2 bemestingssystemen Stap 1 CO2 Nacht...

Page 31: ...n als ook corrosieschade aan de drukregelaar of het ma gneetventiel door teruglopend water zijn van garantie uitgesloten In de garantietijd krijgt u een gratis omruil of een gratis reparatie van het defecte product Voorwaarde hiervoor is het gebruik zoals bedoeld van het product Het product mag in de garantie tijd alleen worden geopend door de Dennerle klantenservice anders vervalt de garantie aan...

Reviews: