8. 

Loading the default (factory) settings

 

When  necessary,  the  factory  (default  settings)  may  be  applied  so  the 

DAEnetIP4

 

parameters will be loaded back. 

 

 

Figure 24.

 System port JP5 

 

When 

DAEnetIP4

  is  shipped  from  the  factory,  the  jumper  is  placed  on  JP5  pins  2 

and 3.

 

 



  Turn off the power supply of the device; 



  Move the jumper to the 

Default Position 

(between pin 1 and 2); 



  Turn on the power supply of the device; 



  Wait until the status led become ON (approximately 10 sec); 



  Remove the jumper from the 

Default Position



  Turn off the power supply of the device; 



  Move back the jumper to the middle position (between pin 2 and 3); 



  The module is configured with default settings. 

 

Summary of Contents for DAE-PB-RO12-12V/DI8/AI8+DAEnetIP4

Page 1: ...Page 1 DAEnetIP4 SNMP 12 Channel I O Relay Module User s Manual Date 19 June 2018...

Page 2: ...out this document 3 2 Overview 4 3 Relay Outputs 5 4 Digital Inputs counters 8 5 Analog Inputs 11 6 PWM Outputs 14 7 Installation 15 8 Loading the default factory settings 21 9 Restart the module 22 1...

Page 3: ...the device DAEnetIP4 Internet Ethernet 12 Channel Relay Board I O SNMP Web This module consist of DAEnetIP4 controller and extension I O relay board which is the main object of this document For full...

Page 4: ...inputs are combined with 16 bit cyclic counters as well 8 x analog inputs 0 10VDC 2 x PWM outputs coming from DAEnetIP4 Led indicators for relays digital inputs power on Sensor supply output Some of...

Page 5: ...5 Switching parameters A A A A 10 28 VDC 15 120 VAC 10 250 VAC Table 2 Mapping to DAEnetIP4 JP1 JP3 digital output port Digital output pin DAEnetIP4 JP1 and JP3 Relay from peripheral board Digital Out...

Page 6: ...control 3 1 2 Example SNMP commands o SNMP GET COMMANDS Get Relay 1 State snmpget v1 c read 192 168 1 100 1 3 6 1 4 1 42505 1 2 3 1 11 0 DENKOVI MIB DigitalOutputState 0 INTEGER off 0 Get Relay 12 St...

Page 7: ...11 i 1 DENKOVI MIB DigitalOutputState 11 INTEGER on 1 Set all relays states with single command snmpget v1 c read 192 168 1 100 1 3 6 1 4 1 42505 1 3 2 0 i 65535 DENKOVI MIB DigitalOutputsState 0 INT...

Page 8: ...nputs electrical characteristics Type Peripheral board Digital inputs count 8 Nominal value of inputs Voltage Current VDC mA 12 5 2 Max non desctructive voltage VDC 30 0 Input switching limit values F...

Page 9: ...4 1 42505 1 2 1 1 7 0 DENKOVI MIB DigitalInputState 0 INTEGER off 0 Get Counter1 Value snmpget v1 c read 192 168 1 100 1 3 6 1 4 1 42505 1 2 1 1 7 0 DENKOVI MIB DigitalInputCounter 0 INTEGER 12345 Get...

Page 10: ...Page 10 4 2 How to use the digital inputs Figure 7 How to use digital inputs...

Page 11: ...isor is calibrated to work in the 0 10V DC range The input voltage range of 0 10V DC can be changed up on request The resistors used for building the module are 5 The ADC of the DAEnetIP4 also have so...

Page 12: ...ts at maximum voltage determinated by parameter determinated by parameter Isolation Beteen analog channel and supply No Protection Against reverse polarity Yes Table 6 Mapping to DAEnetIP4 JP4 analog...

Page 13: ...log Inputs 5 1 1 Web browser Figure 10 Monitoring and Control web page Analog Inputs monitoring 5 1 2 Example SNMP commands Get Ain1 Level snmpget v1 c read 192 168 1 100 1 3 6 1 4 1 42505 1 2 2 1 6 0...

Page 14: ...Outputs The PWM outputs are those from DAEnetIP4 For more information please refer to the DAEnetIP4 documentation http denkovi com Documents DAEnetIP4 Current Version UserManual pdf Figure 11 PWM out...

Page 15: ...2 Power supply requirements Figure 12 Location of DAEnetIP4 12 Relay Module power jack The whole module has the following current consumption 400mA at 24V DC and all relays are ON 700mA at 12V DC and...

Page 16: ...commended to reverse the voltage polarity DAEnetIP4 12 Relay Module does not accept AC supply voltage It is highly recommended to check the power supply source parameters before turning on the module...

Page 17: ...ter directly recommended initial connection Figure 17 Connecting DAEnetIP4 12 Relay Module to a wireless router 7 4 Communication setup DAEnetIP4 is shipped with the following default parameters IP ad...

Page 18: ...r IP settings or just visit this web page http www howtochangeipaddress com changeip php For Windows 7 OS for example you can do that in the following way Navigate to Control Panel Network and Interne...

Page 19: ...Page 19 The next step is to enter into IPv4 properties Figure 19 Enter in IPv4 properties section Set the IP address of your PC to be in the same network Figure 20 Set the IP address...

Page 20: ...our browser 192 168 1 100 Figure 21 Open the device via browser If the network settings are O K the log in page should appear Figure 22 Login page DAEnetIP4 modules connected locally can be easily sca...

Page 21: ...jumper is placed on JP5 pins 2 and 3 Turn off the power supply of the device Move the jumper to the Default Position between pin 1 and 2 Turn on the power supply of the device Wait until the status le...

Page 22: ...plug the power supply wait 10 seconds and plug it again Move the jumper to Reset Position Figure 24 wait 10 seconds and then get it back to it s old position This option is most suitable when the cont...

Page 23: ...Page 23 10 PCB dimensions...

Reviews: