![Denison Hydraulics P140 A-mod Service Information Download Page 3](http://html1.mh-extra.com/html/denison-hydraulics/p140-a-mod/p140-a-mod_service-information_2480237003.webp)
3
Specification
• compensator response
off-stroke
on-stroke
• compensator adjustment
• minimum compensating pressure (comp, torque limiter)
• minimum compensator override pressure (servo, electric
& hyd. str.)
• torque limiter adjustment range
code J
code K
• typ. servo & stroker response @ 83 bar servo pressure,
zero to full stroke and vice versa
• servo flow required for this response (E, H, R10 controls)
• servo flow required for this response (*1J, *1K, *1P
controls)
• maximum servo pressure
• servo shaft rotation, 0 to full volume
• displacement/rev./degree servo shaft rotation
• hydraulic stroker control pressure
0 displacement
full displacement
• electric stroker control amps (24v.)
0 displacement
full displacement
pulse width modulation frequency:
mating connector: Din 43650 type AF
part no. 167-10008-8 (provided)
• electric stroker nominal coil resistance (24v. coil)
• electric stroker nominal coil resistance (12v. coil)
• handwheel turns, full to zero stroke
• torque to turn handwheel @ 70 bar
• torque to turn handwheel @ 500 bar
• torque to turn rotary servo shaft
• port C1, C2 (cylinder gage ports)
• port E (electric stroker control pressure inlet)
• port H (hydraulic stroker control pressure inlet)
• port LS (load sensing port)
• port V (compensator vent)
• port X (rotary servo, electric & hydraulic stroker servo
inlet)
Term
sec.
sec.
bar/turn
bar
bar
Nm
Nm
sec.
l/min.
l/min
bar
degrees
cc/rev/deg.
bar
bar
mA
mA
Hz
ohms
ohms
turns
Nm
Nm
Nm
BSPP
BSPP
BSPP
BSPP
BSPP
BSPP
P260
0,100
0,150
138
17,2
93,1
282 - 706
706 - 1129
<0,6
11,4
15,2
103
80
3,25
3,45
19
150-200
390
100-150
41
10
10
17
40
2,3
1/4
1/4
1/4
1/4
3/8
3/8
TYPICAL CHARACTERISTICS
FLUID CONNECTIONS
CHARACTERISTICS
www.comoso.com