Denios bio.x T700 User Manual Download Page 9

User Manual 

 

 

 bio.x T700 160416 

Page 9 of 15   

Issued 10/2010 

 

6.1 Energy-saving mode 

The unit can be switched to energy-saving mode during downtimes such as night-time, weekends, or company 
holidays as long as you like.  

 

The temperature is maintained at 30º C in energy-saving mode. The micro-organisms remain active at this 
temperature and optimum oil and grease degradation is guaranteed. 

Settings: 

1)  Press the multi-function button for > 3 

 

A 2-digit number appears in the display (time period for 
the energy-saving mode, last set value),  
the first digit is flashing. 

2)  Press the multi-function button for a 

short time  

 

The flashing digit will count up (0 will follow after 9) 

3)  Press the multi-function button for > 2 

 

The 2nd digit flashes 

4)  Press the multi-function button for a 

short time 

 

The flashing digit will count up (0 will follow after 9) 

5)  Press the multi-function button for > 2 

 

The set time is displayed alternately with the „30“ for the 
energy saving mode.  
The display of the hours refers to the remaining time 
until the unit is switched on again 
(hour or part thereof) 

If the operator does not set any time, the displayed value will be taken over automatically after 10 s. If the 
value"00" is set, the time control function is not used and the energy-saving mode must be terminated by pressing 
the multi-function button for a short time.  

After the energy-saving mode has been terminated, the unit heats the cleaning fluid up to 41 °C. The warm-up 
stage takes about an hour, depending on the ambient temperature. Once this temperature is reached and "41" is 
shown continuously on the display, the unit is ready for operation with optimum cleaning assured.  

 

6.2 Controllable pump run time  

(Control unit # 190379 with software version V1.12 and later) 

The pump run time can be preselected with fixed values. This is reasonable for automatic cleaning, e.g. when the 
optional immersion basket set or the spray unit is used. 
 
For this purpose, 5, 10, 15 or 60 (basic setting) minutes are available. During the reduced pump run time (5, 10, 
15 minutes), the remaining run time is displayed in minutes. 

Settings: 

1)  Press the multi-function button for a 

long time > 10 s 

 

If the set pump run time is reached, number „05“ will be 
displayed. 
 
(After 3 s, ‘00’ is displayed while the first digit is flashing 
– continue to press and hold the multifunction button) 

2)  Press the multi-function button for a 

short time 

 

Set the pump run time in the steps of 5, 10, 15 60 
minutes 

3)  Press the multi-function button for   

for > 2 s 
 

 

The setting will be accepted 

The set pump run time is then used for the following cleaning processes. The pump is automatically switched off 
after the time period has passed.  

After the unit has been switched off (pulling of the plug) or after power failure, the basic setting of 60 minutes will 
be active again.  

 

Summary of Contents for bio.x T700

Page 1: ...hmer Stra e 58 66 D 32549 Bad Oeynhausen Phone 49 0 5731 7 53 122 Fax 49 0 5731 7 53 95 951 Email customerservice denios de You can find your local contact person on our Internet site www denios com 0...

Page 2: ...tors on the display 8 6 Operation 8 6 1 Energy saving mode 9 6 2 Controllable pump run time 9 7 Maintenance 10 7 1 Filter 10 7 2 Filling level 10 7 3 Suction filter 6 10 7 4 Cleaning fluid 10 7 5 Fine...

Page 3: ...n being paid to prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons...

Page 4: ...rane pump with dry operation protection operating pressure approx 6 bar flow rate 4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister On and Off 150097 9 On...

Page 5: ...nt pane Polycarbonate scratch proof coated Surround seal lock and reach through gauntlet gloves Item Designation Mat No 24 Hood with transparent pane sealing hook rails 189654 25 Reach through gauntle...

Page 6: ...User Manual bio x T700 160416 Page 6 of 15 Issued 10 2010 1 13 10 24 9 23 16 12 21 26 27 24 28 30 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...

Page 7: ...mains On will be shown on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating tem...

Page 8: ...Close the cover If necessary turn on the light with the on off switch 9 You can also switch on off 30 the demister unit of the transparent hood Reach for the cleaning equipment through the gauntlets...

Page 9: ...ssing the multi function button for a short time After the energy saving mode has been terminated the unit heats the cleaning fluid up to 41 C The warm up stage takes about an hour depending on the am...

Page 10: ...sits If the suction filter is so dirty that it can no longer be cleaned in this way it has to be replaced 7 4 Cleaning fluid The cleaning fluid has to be replaced if there is a significant fall in the...

Page 11: ...s 4 x 5 litre canisters 187609 Cleaning fluid bio x 20 litre canister 130032 Cleaning fluid bio x 200 litre drum 161524 Set for initial filling and refills 5 x 20 litre canisters 130030 7 8 Replacemen...

Page 12: ...torage area on the back wall of the upper part can be connected without tools 161640 Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting...

Page 13: ...connected or is faulty 2 Fuse faulty 1 Connect aerator replace if necessary 2 Replace fuse F 4 Level switch not working Level switch not connected Connect level switch F 5 Short circuit in level swit...

Page 14: ...User Manual bio x T700 160416 Page 14 of 15 Issued 10 2010 11 Circuit diagram of the electric control unit...

Page 15: ...eclare that the product type Parts Cleaner bio x T700 complies with the following directives EC Directives 2006 42 EC 2004 108 EC Applied harmonized standards EN 349 EN 12100 1 2 EN 60204 1 EN 12981 1...

Reviews: