8. Optional Accessories 

Accessories 

Description Part 

number 

Residual current device 
adapter 

Adapter for fuse protection for the appliance  
Trigger current: 30 mA, 
Protective system: 

IP44 

177335 

Protective gloves 
(1 pair) 

with extra long gauntlet, internally padded with cotton fabric 
Length:  

640mm 

Size:  

10 

EN388:  

4121 

Resistance: 

good protection against detergents, alkali, oil and 

grease 

163613 

Gauntlet gloves 
(1 pair) 

Chemical protection gloves in accordance with EN 420 (4 1 2, 1) and 
EN 374 
Material: PVC 
Polyurethane colour:   red-brown 
Length:   approx. 70 cm 
Size: 

9 / 10 

176234 

Filter 

The additional fine filter can be installed between the pump and 
return flow.  

161718  

Filter screen type 454 
Filter 80 

μ

Can be used as an alternative for filter screen (12) 

161047  

Compressed-air pistol 

With a hose and connector assembly installed in the upper part of 
the parts cleaning unit it speeds up the drying of the cleaned parts 

160419  

Stainless steel storage 

An additional storage area on the back wall of the upper part, can be 
connected without tools 

161640  

Perforated metal insert 

To protect the work surface of the cleaning table 
Makes it possible to work without tilting 

169227  

Interior lighting  

Protective tube light IP67, 1x24W 

160425 

Rolling cart 

For the portable use of the parts cleaning unit 

154288  

Offset brush

 

For cleaning nooks and corners, prevents signs of fatigue when 
working for a long time. 

172560 

Stainless steel brush 

To remove heavily crusted dirt from insensitive parts 

173926 

Wet vacuum cleaner  
Type SV 6.16 

To completely empty the tank, also suitable for sludge 

123224 

Spray unit 

Spray unit for preliminary cleaning 

187665 

Immersion basket set 

Allows soaking of heavily polluted parts 

186506 

 

9. Instructions for waste disposal

 

Cleaning fluid 

The relevant waste code number for a contaminated substance depends on the type of dirt removed and not on the 
type of detergent. The applicable waste code number can be found in the European Waste Catalogue. 
Contaminated substances can often be disposed off with other hydrous systems. 
Unused fluids can be fed into waste water treatment plant while taking into account local regulations regarding 
waste water disposal. 

 

 

 

 

 

Summary of Contents for bio.x T700

Page 1: ...hmer Stra e 58 66 D 32549 Bad Oeynhausen Phone 49 0 5731 7 53 122 Fax 49 0 5731 7 53 95 951 Email customerservice denios de You can find your local contact person on our Internet site www denios com 0...

Page 2: ...tors on the display 8 6 Operation 8 6 1 Energy saving mode 9 6 2 Controllable pump run time 9 7 Maintenance 10 7 1 Filter 10 7 2 Filling level 10 7 3 Suction filter 6 10 7 4 Cleaning fluid 10 7 5 Fine...

Page 3: ...n being paid to prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons...

Page 4: ...rane pump with dry operation protection operating pressure approx 6 bar flow rate 4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister On and Off 150097 9 On...

Page 5: ...nt pane Polycarbonate scratch proof coated Surround seal lock and reach through gauntlet gloves Item Designation Mat No 24 Hood with transparent pane sealing hook rails 189654 25 Reach through gauntle...

Page 6: ...User Manual bio x T700 160416 Page 6 of 15 Issued 10 2010 1 13 10 24 9 23 16 12 21 26 27 24 28 30 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...

Page 7: ...mains On will be shown on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating tem...

Page 8: ...Close the cover If necessary turn on the light with the on off switch 9 You can also switch on off 30 the demister unit of the transparent hood Reach for the cleaning equipment through the gauntlets...

Page 9: ...ssing the multi function button for a short time After the energy saving mode has been terminated the unit heats the cleaning fluid up to 41 C The warm up stage takes about an hour depending on the am...

Page 10: ...sits If the suction filter is so dirty that it can no longer be cleaned in this way it has to be replaced 7 4 Cleaning fluid The cleaning fluid has to be replaced if there is a significant fall in the...

Page 11: ...s 4 x 5 litre canisters 187609 Cleaning fluid bio x 20 litre canister 130032 Cleaning fluid bio x 200 litre drum 161524 Set for initial filling and refills 5 x 20 litre canisters 130030 7 8 Replacemen...

Page 12: ...torage area on the back wall of the upper part can be connected without tools 161640 Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting...

Page 13: ...connected or is faulty 2 Fuse faulty 1 Connect aerator replace if necessary 2 Replace fuse F 4 Level switch not working Level switch not connected Connect level switch F 5 Short circuit in level swit...

Page 14: ...User Manual bio x T700 160416 Page 14 of 15 Issued 10 2010 11 Circuit diagram of the electric control unit...

Page 15: ...eclare that the product type Parts Cleaner bio x T700 complies with the following directives EC Directives 2006 42 EC 2004 108 EC Applied harmonized standards EN 349 EN 12100 1 2 EN 60204 1 EN 12981 1...