7.7 Refill units 

Accessories Description 

Item 

number

Concentrate bio.x (mixing proportion 1:4)  5-litre canister 

183543 

Set concentrate for initial filling and refills  4 x 5-litre canisters  187609 

Cleaning fluid bio.x 

20-litre canister 

130032 

Cleaning fluid bio.x 

200-litre drum 

161524 

Set for initial filling and refills 

5 x 20-litre canisters 130030 

 

7.8 Replacement parts (see also product description page 4+5) 

Accessories Description 

Part 

number 

Transparent pane with sealing  Transparent pane of hood 

186914 

Filter housing 

Fine filter (161718) 

160703 

Replaceable sieve insert  

200

μ

m 162522 

Summary of Contents for bio.x T700

Page 1: ...hmer Stra e 58 66 D 32549 Bad Oeynhausen Phone 49 0 5731 7 53 122 Fax 49 0 5731 7 53 95 951 Email customerservice denios de You can find your local contact person on our Internet site www denios com 0...

Page 2: ...tors on the display 8 6 Operation 8 6 1 Energy saving mode 9 6 2 Controllable pump run time 9 7 Maintenance 10 7 1 Filter 10 7 2 Filling level 10 7 3 Suction filter 6 10 7 4 Cleaning fluid 10 7 5 Fine...

Page 3: ...n being paid to prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons...

Page 4: ...rane pump with dry operation protection operating pressure approx 6 bar flow rate 4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister On and Off 150097 9 On...

Page 5: ...nt pane Polycarbonate scratch proof coated Surround seal lock and reach through gauntlet gloves Item Designation Mat No 24 Hood with transparent pane sealing hook rails 189654 25 Reach through gauntle...

Page 6: ...User Manual bio x T700 160416 Page 6 of 15 Issued 10 2010 1 13 10 24 9 23 16 12 21 26 27 24 28 30 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...

Page 7: ...mains On will be shown on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating tem...

Page 8: ...Close the cover If necessary turn on the light with the on off switch 9 You can also switch on off 30 the demister unit of the transparent hood Reach for the cleaning equipment through the gauntlets...

Page 9: ...ssing the multi function button for a short time After the energy saving mode has been terminated the unit heats the cleaning fluid up to 41 C The warm up stage takes about an hour depending on the am...

Page 10: ...sits If the suction filter is so dirty that it can no longer be cleaned in this way it has to be replaced 7 4 Cleaning fluid The cleaning fluid has to be replaced if there is a significant fall in the...

Page 11: ...s 4 x 5 litre canisters 187609 Cleaning fluid bio x 20 litre canister 130032 Cleaning fluid bio x 200 litre drum 161524 Set for initial filling and refills 5 x 20 litre canisters 130030 7 8 Replacemen...

Page 12: ...torage area on the back wall of the upper part can be connected without tools 161640 Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting...

Page 13: ...connected or is faulty 2 Fuse faulty 1 Connect aerator replace if necessary 2 Replace fuse F 4 Level switch not working Level switch not connected Connect level switch F 5 Short circuit in level swit...

Page 14: ...User Manual bio x T700 160416 Page 14 of 15 Issued 10 2010 11 Circuit diagram of the electric control unit...

Page 15: ...eclare that the product type Parts Cleaner bio x T700 complies with the following directives EC Directives 2006 42 EC 2004 108 EC Applied harmonized standards EN 349 EN 12100 1 2 EN 60204 1 EN 12981 1...