12
DENGENSHA
No.
Item
Specification
10 Ambient temperature
0
~
40[
℃
]
under charging
:
5
~
30[
℃
]
11 Humidity
90% or less, no dew drop
12
Measuring resistance welder
type
Single phase AC, single-phase rectifier,
three-phase rectifier, MFDC
Note) Maximum no load secondary voltage is 33V rms or less for
operator safety.
13 Frequency
50/60Hz
*Note Initial setting value is 50Hz, please be sure to set
frequency of user region (see 7.7 of this manual)
14 Current sensor type
ISO type :150mV/1000A
※
Option 10 times of sensitivity, 1/2 times of sensitivity
manual sensor voltage setting is also available
15 Measurement current ranges
AC
:
0.60
~
6.00(kA),2.5
~
25.0(kA), 5.0
~
50.0(kA)
DC
:
1.00
~
10.00(kA),2.5
~
25.0(kA),5.0
~
50.0(kA)
16 Measuring time range
0.5
~
99[cyc]
17 Measurement accuracy
±
2% F.S.
18 Phase range
30 – 180[
°
]
19 Maximum storage data
Average RMS current and time
:
10,000 weld points
RMS current of each cycle
:
50 weld points
Waveform
:
3 weld points
20 PC communication interface
USB Type B (PC connection cable is TypeB-TypeA)
21
Pressure meter range
(with option pressure sensor)
0.5 - 10.0[kN]
Summary of Contents for WS-100
Page 2: ......
Page 3: ......
Page 7: ...v DENGENSHA ...
Page 36: ...DENGENSHA Memo ...
Page 37: ...DENGENSHA Memo ...
Page 38: ...DENGENSHA Memo ...