![Den-Sin C-200AIR User Manual & Spare Parts Manual Download Page 6](http://html.mh-extra.com/html/den-sin/c-200air/c-200air_user-manual-and-spare-parts-manual_2479934006.webp)
1. Getting acquainted with your High Pressure Cleaner
C-200Air V16
Page 5
P
repare the water supply for the High Pressure Cleaner by attaching a hose
to the supplied low pressure inlet male-coupling. Connect the other end of
the water supply hose to a potable water tap. Turn on tap.
Connect to the public mains water supply in accordance to
regulations.
B
efore starting the machine, bleed out air by pulling the trigger-gun handle until any air has
escaped the inlet hose. Release trigger once water flow is smooth at the outlet.
C
onnect the air supply hose into the coupling provided and attached the
coupling to the machine once supply line is secured. Secure the coupling
onto the machine by depressing the 2 locking lever downwards. Power up
machine by turning on the air supply
A
djust the air pressure of the FRL unit by turning the
pressure regulator knob as shown until water pressure
is achieved.
T
he high pressure cleaner is now ready for
operation. The spray-gun lance is affected by a
recoil force during operation – therefore keep a
firm grip with both hands on the Spray-gun
handle and the lance. Press the trigger and tighten
pressure regulating knob to achieve maximum
pressure for effective cleaning.
Notice
Depress Trigger
Knob fully tighten
Pressure Regulator