Technical
Specifications
Tempest
1
/
Auto
/
Cabinet
Washer
240V
(
Blue
Cable)
Pump
XT11.11
Boiler
Pump
pressure
100
bar
1500psi
Fuel
type
Kerosene/gas
oil/derv
Flow
rate
111pm
2.45gpm
Pressure
7
bar
110psi
Max
by
‐
pass
setting
110
bar
1650psi
Nozzle
1.5
US
galls
Min
pressure
setting
50
bar
750psi
Nozzle
make
Monarch
60°R
or
AR
Danfoss
60°
S
H.P
nozzle
25045
Electrode
gap
6mm
±
1mm
Motor
power
2.2KW(MTR00100)
Ignition
Transformer
70
Watts
Pump
oil
10W40
Fuel
pump
50
Watts
Unloader
valve
ARMM4B/TSS
Fan
motor
75
Watts
Noise
Fuse001
1
amp
semi
delay
20mm
glass
Valve
Kit
ARKIT1864
Oil
Seal
Kit
ARKIT1872
Seal
Kit
ARKIT1874
Piston
Kit
ARKIT2629
Generator
Size
required
6KVA
Tempest
3
/
Auto
110V
(Yellow
Cable)
Pump
XT11.11
Boiler
Pump
pressure
100
bar
1500psi
Fuel
type
Kerosene/gas
oil/derv
Flow
rate
11
lpm
2.45gpm
Pressure
7
bar
100psi
Max
by
‐
pass
setting
110
bar
1650psi
Nozzle
1.5
US
galls
Min
pressure
setting
50
bar
750psi
Nozzle
make
Monarch
60°R
or
AR
Danfoss
60°
S
H.P
nozzle
25045
Electrode
gap
6mm
±
1mm
Motor
power
2.2KW(MTR00301)
Ignition
Transformer
70
Watts
Pump
oil
10W40
Fuel
pump
50
Watts
Unloader
valve
ARMM4B/TSS
Fan
motor
75
Watts
Noise
Fuse002
3
amp
semi
delay
20mm
glass
Valve
Kit
ARKIT1864
Oil
Seal
Kit
ARKIT1872
Water
Seal
Kit
ARKIT1874
Piston
Seal
Kit
ARKIT2629
Generator
size
required
8KVA
Tempest
4
/
Auto
/Cabinet
Washer
415V
(Black
Cable)
(
From
the
03/07/12
ARGM3
unloader)
Pump
RK15.20H
Boiler
Pump
pressure
200bar
2900psi
Fuel
Type
kerosene/gas
oil/
derv
Flow
rate
151pm
Pressure
7
Bar
110psi
Max
by
‐
pass
setting
200bar
2900psi
Nozzle
1.75
US
galls
Min
pressure
setting
50bar
750psi
Nozzle
make
Monarch
60
0
R
or
AR
Danfoss
60
0
S
H
P
Nozzle
2505
Electrode
gap
6mm
+
1mm
Motor
power
7.5KW(MTR00220)
Ignition
Transformer
70watts
Pump
oil
10W40
Fuel
pump
50watts
Old
Unloader
Valve
ARMM4B/TSS
New
Unloader
Valve
ARGM3
fan
Motor
75watts
Noise
Fuse001
1amp
semi
delay
20mm
glass
‐
Valve
Kit
ARKIT1828
Water
Seal
Kit
ARKIT1857
Oil
Seal
Kit
ARKIT1856
Piston
ARKIT2757
Tempest
Cabinets
fitted
with
low
water
and
low
fuel
cut
out
sensors
Summary of Contents for Tempest 1
Page 9: ......
Page 10: ......
Page 17: ......
Page 19: ......
Page 20: ......
Page 21: ...HH0049 3 8 Ferrules R1A HH0053 Hose from Pump to Tap 1 2 L P Yellow Hose...
Page 27: ......
Page 31: ...Frost Stat Heater Coil all cabinets 240v Heater Coil Thermostat L N E KTW 12 3 13 1 2 3 4...