The
Tempest
Cabinet
washer
is
simple
to
install,
there
are
four
holes
in
the
feet
for
bolting
to
a
solid
sur
‐
face
such
as
a
concrete
plinth
and
a
10
mm
masonry
drill
can
be
drilled
to
a
depth
to
suit
either
raw
bolts
or
sleeve
anchors.
The
water
supply
is
via
a
standard
hose
pipe
to
a
tap
and
there
is
a
stepped
nipple
to
suit
13
mm
and
19
mm
pipe.
Electricity
supply
must
be
wired
by
a
competent
electrician
and
we
recommend
the
supply
is
wired
using
armoured
cable
with
an
isolator
nearby.
If
a
separate
supply
is
required
for
the
frost
protection
system
then
this
must
be
installed
upstream
of
the
isolator
so
the
heater
will
work
even
if
the
mains
supply
is
turned
off.
A
fused
spur
is
ideal
for
this
application.
230V
model
–
needs
a
D20
MCB
on
your
distribution
panel
415V
model
–
needs
a
D20
triple
MCB
on
your
distribution
panel
Both
models
–
separate
feed
for
frost
protection
5
amp
fused
spur
Prolonged
periods
of
cold
weather
In
prolonged
periods
of
cold
weather
we
advise
turning
the
water
off
and
running
the
machine
until
it
is
empty
then
disconnect
all
hoses
and
isolate
from
the
mains
power
but
leaving
the
frost
protection
circuit
live
to
give
some
heat
inside
the
cabinet.
Tempest
Cabinet
Washer
‐
Installation
Instructions
Summary of Contents for Tempest 1
Page 9: ......
Page 10: ......
Page 17: ......
Page 19: ......
Page 20: ......
Page 21: ...HH0049 3 8 Ferrules R1A HH0053 Hose from Pump to Tap 1 2 L P Yellow Hose...
Page 27: ......
Page 31: ...Frost Stat Heater Coil all cabinets 240v Heater Coil Thermostat L N E KTW 12 3 13 1 2 3 4...
Page 32: ......
Page 33: ......
Page 34: ......
Page 36: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 46: ...Pump for Tempest 1 and Tempest 3...
Page 48: ...For Tempest 1 and Tempest 3...
Page 50: ...Pump for Tempest 4 RK 13 17 RK 15 20H RK21 15...
Page 52: ......
Page 54: ......