6  Function check after installation

A general function check of the radio receiver is possible by means of the light 
diodes on the radio receiver card.

  The yellow LED flashes, when the receiver is supplied with current and no 

DRC-10 hand-held transmitter or DRC-J joystick control system has been 
assigned yet. In addition, a red LED flashes, when radio telegrams of DRC-10 
or DRC-J radio transmitters that have not been assigned are received.

  The green LED flashes, when the receiver is supplied with current and radio 

telegrams of an assigned DRC-10 or DRC-J radio transmitter are received. 
When the DRC-10 or DRC-J radio transmitter is in Stop mode, the flashing 
 sequence is approx. 5/sec.

 When the DRC-10 or DRC-J radio transmitter is in Run mode, the flashing 
sequence changes to rapid 10/sec.Further function checks are only possible 
by operation of a corresponding radio transmitter (DRC -10 or DRC J). For this 
purpose, please use the relevant operating instructions of the respective DRC-10 
or DRC-J radio transmitter and of the crane installation (see accompanying 
documents, page 2).
You will also find relevant instructions for eliminating possible faults of a radio con-
trol system in the operating instructions of the DRC-10 or DRC-J radio transmitter 
and the crane installation.

When delivered, the DRC-DR radio receiver has crane identification “NOID”. 
All crane movements are blocked.  This block is removed when the unit is put into 
operation by a valid crane identification (other than NOID) being assigned to the 
receiver.
The radio receiver can be put into operation by means of the relevant radio trans-
mitter (DCR-10 or DRC-J). The procedure for putting the radio remote control 
system into operation is described in detail in the operating instructions of the 
transmitter.
Operating instructions required in addition:

Radio transmitter 

 

Part no.

DRC-10 hand-held transmitter  

 

214 920 44

DRC-J transmitter operating instructions  

214 975 44.

6.1  Putting the receiver 

into operation for the 
first time

Summary of Contents for DRC-DR D2

Page 1: ...Operating instructions DRC DR D2 radio receiver...

Page 2: ...Transmission method 10 4 Technical data 12 5 Fitting the radio receiver card 13 6 Function check after installation 15 6 1 Putting the receiver into operation for the first time 15 7 International pos...

Page 3: ...ld only be used by authorized personnel They may only be entrusted or made available to third parties with the prior written consent of Demag All documents are protected within the sense of copyright...

Page 4: ...llustrations and descriptions contained in these operating instructions The descriptions and illustrations contained in this documentation do not neces sarily correspond to the scope of delivery or an...

Page 5: ...tandards codes of practice and regulations are able to assess the tasks given to them and to identify and eliminate potential hazards Trained person Trained persons are defined as persons who have bee...

Page 6: ...d control equipment control pen dant can be dispensed with The operator can position himself as required He can freely move loads from a safe distance in line with the local conditions DRC DR radio re...

Page 7: ...fic transmitter and the corresponding receiver Radio remote control systems of the DRC range may only be operated when in perfect working order by trained personnel in accordance with the relevant saf...

Page 8: ...jury and damage to machinery The operating instructions must be kept available at the place where the product is in use at all times They include significant aspects and appropriate excerpts from the...

Page 9: ...sm All safety and hazard warnings on the product its access routes and mains con nection switches must be preserved completely and in legible condition Modifications additions to and conversions of th...

Page 10: ...ck generator detemines the sequence of the frequencies when radio transmission is started In order to increase transmission reliability the information is transmitted several times This method in conn...

Page 11: ...431 44 OK OK not compatible not compatible not compatible D1 DRC J 773 460 44 OK OK not compatible not compatible not compatible D1 FH DRC 10 773 581 44 Fixed frequency Fixed frequency OK OK OK D1 FH...

Page 12: ...itter receiverl HF available Data telegrams decoded without error Type of enclosure IP 55 integrated in rope hoist controls Ambient temperature 20 to 70 C Weight of radio receiver 60 g Supply voltage...

Page 13: ...ore starting any installation work disconnect system from the power supply Install the radio receiver card in the appropriate slot Fix the radio receiver card in the electrical equipment cover by mean...

Page 14: ...tallation of the radio receiver card has been complet ed Before the system is put into operation again make sure that other control components such as for example the DSE 8R or DSE 10R control pendant...

Page 15: ...RC 10 or DRC J For this purpose please use the relevant operating instructions of the respective DRC 10 or DRC J radio transmitter and of the crane installation see accompanying documents page 2 You w...

Page 16: ...witzerland 433 MHz ISM band Slovakia 433 MHz ISM band Slovania 433 MHz ISM band Spain 433 MHz ISM band Sweden 433 MHz ISM band Czech Republic 433 MHz ISM band Germany 433 MHz ISM band Hungary 433 MHz...

Page 17: ...emag radio control system RC 10 RC J DRC 10 DRC J DRC MP DRC DR DRC DC 1 of serial design is in conformity with the provisions of following relevant regulations EC EMC directive 89 336 EEC amended by...

Page 18: ...18 21495344 indd 311007...

Page 19: ...19 21495344 indd 311007 Operating instructions Programming parameters of DRC DR radio receiver For authorized personnel only...

Page 20: ...io receiver Note Parameters 001 to 003 only refer to radio receivers with CAN interface and are only effective for these Parameters 001 to 003 are set in the factory and must not be changed without pr...

Page 21: ...quals symbol Instead of the current value of a parameter one of the possible values is now displayed 1 4 Entry mode Scrolling through possible values DRC 10 Left and right keys DRC J Display keys and...

Page 22: ...splay key Exit entry mode F2 F2 Accept the displayed Baud rate Precondition Parameter code 002 activated The default setting set in the factory is node ID 1 In the display the current node ID of the r...

Page 23: ...transmitter Since the radio control permanently displays the crane identification in the upper main row of the display only number sequence 000 is shown in the second main row To navigate use the foll...

Page 24: ...ting the entered crane identification with F2 the crane identification will remain unchanged entry is aborted When the crane identification has been changed it may be necessary to log an older DRC 10...

Page 25: ...menu The hardware version number of the radio receiver is displayed with parameter 007 It is only provided for information and cannot be changed To navigate use the following keys DRC 10 DRC J Functi...

Page 26: ...26 21495344 indd 311007 Notes...

Page 27: ...27 21495344 indd 311007 Notes...

Page 28: ...Reproduction in whole or in part only with prior consent of Demag Cranes Components GmbH D 58286 Wetter Subject to change Not liable for errors or omissions Printed in Germany...

Reviews: