I-917
Page 2 of 4
REV. D-36759 4/7/11
Power
selection
switch
PARTS CHECKLIST BY OLYMPIAN MODEL
Blue - Rinse
Sanitizer
ITEM PART
NO.
DESCRIPTION
O-RHV O-RDV O-SDV
904-8T
Rinse – Injection Check Valve
1
1
-
1.
904-8P
Sanitizer – Injection Check Valve
-
-
1
2.
61-107-2
Ceramic Weight
1
1
1
3.
100-12SV1
Tubing Vinyl ¼”OD x 1/6”ID
1
1
1
4.
30-37
Screw
3
3
3
5.
66-121
Wall Anchor
3
3
3
6.
81-248-1
Weight Retainer
1
1
1
ELECTRICAL INSTALLATION:
All installations must be in accordance with city, county, parish, state, or provincial electrical codes and be performed by a
certified electrician. For questions, please contact a local licensed electrical contractor.
1.
All electrical power must be turned off to the dish or
cleaning machine and any other circuit that is to be used
for this installation. Lockout and tag procedures must be
observed when installing this device. Never open the
Olympian enclosure while power is applied. Signals may
be active from the dish or cleaning machine, even with
Olympian power turned off. Use appropriately rated
insulated wiring, electrical fixtures, and other materials
that meet all applicable electrical and building codes.
2.
O-RDV/SDV Controls Only:
This control has a switch
to select the proper line voltage. The unit is factory set to
230VAC. To change the voltage to 115VAC, remove the
back of the control. Move the switch from 230VAC to
115VAC as shown in Figure 1. Reinstall the back cover.
WARNING: This must be done before connecting power to the unit.
3.
Connect to the appropriate power source.
TUBING INSTALLATION:
1.
Install weight and weight retainer as shown in Figure 2.
2.
Place weight and retainer in chemical container.
3.
Cut tubing to the appropriate length. Attach tubing to the pump inlet.
4.
Attach outlet tubing to pump outlet and to dish or cleaning machine.
Attach outlet tubing to injection check valve (904-8T or 904-8T).
Brown Wire
Line
Blue Wire
Common
Green/Yellow Wire
Ground
Figure 1. Input Voltage Switch
Figure 2. Tubing, Weight, & Retainer