I-917
Page 3 of 4
REV. D-36759 4/7/11
PROGRAMMING:
NOTE: Due to the short wash and rinse cycles, the programming of the unit may
require several wash cycles.
Step 1: Apply power.
Step 2: Remove the cover and connect the Two Button Programmer as shown in Figure 3.
Step 3: Push either button on the programmer to toggle the LED to the desired program
mode as shown in Figure 4. See below for the program mode.
Step 4: Push both buttons, simultaneously, to start programming the time or enter program
mode.
Step 5: Push both buttons, simultaneously, to stop time or exit the program mode.
Step 6: Repeat steps 3-5 for each program mode.
Step 7: After the Olympian Unit has been programmed with the desired values, remove the
Two Button Programmer from the Olympian programming jack and replace the
Olympian cover.
Program
Mode
LED
Color
Description
Programming
Factory Default Settings
1
Delay Yellow
Amount of time delay
between power and
pumping of rinse additive
Push both buttons to start delay
time and both buttons to stop
delay time
0 Seconds
2
Pump
Speed
Green
Speed of pump
Push both buttons to enter
programming mode. Push left
button to reduce speed. Push
right button to increase speed
100% (Maximum speed)
3
Rinse
Limit
Red
Active = Pump will stop
running after 18 seconds
of power.
Inactive = Pump will run
until power is turned off.
Push both buttons to toggle the
LED on the programmer.
On = Activates rinse limit
Off = Pump runs until power is
turned off
Active
Rinse Limit Indicator
On = Limit is active
Off = Limit is inactive
Figure 3. Programmer Installation
Figure 4. Program Mode Selection