Overall Dimensions 

 

 
Installation & Preparation  

1.  Identify desired location of dispenser.  Remove cardboard mounting template from packaging, place 

against wall and mark hole locations using the template as a guide.   
 
[For accuracy, use level with template to ensure the dispenser is level on the wall] 

2.  Install all four supplied anchors into marked hole locations from step 1.  Using supplied screws, install 

top two screws and hang dispenser from them. Install bottom two screws through dispenser holes 
into the anchors. 
 

3.  Tighten screws against dispenser to assure a secure fit. 

4.  Install Drip Tray by sliding into place against 

tab in back of drip tray holder.  
[Optional: Drill 3/16” hole into drip tray barb and 
attach ¼” ID hose (not supplied) for draining 
chemical from drip tray (

Figure 1

 

Figure 1 

Summary of Contents for 665 Series

Page 1: ...quires the use of a pressure indicating tee ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS Instruction Sheet Contents Operational Requirements Category Page Water Supp...

Page 2: ...e the dispenser is level on the wall 2 Install all four supplied anchors into marked hole locations from step 1 Using supplied screws install top two screws and hang dispenser from them Install bottom...

Page 3: ...revent a product from dispensing at bottle or bucket fill 7 For SafeLink cap and tubing secure the tubing over the exposed check valve barb Figure 3 For Open container Measure bulk tubing needed and c...

Page 4: ...the bottle fill assembly 2 To stop filling lower the bottle and the lever will disengage 3 Be careful when removing the spray bottle so as to not splash residual chemical Figure 7 Dispenser Activatio...

Page 5: ...11 76 85 White 7 00 55 56 18 1 75 13 70 73 Green 7 90 62 50 16 2 00 15 63 64 Blue 9 80 76 92 13 2 50 19 61 51 Yellow 14 80 111 11 9 3 75 39 41 34 Gray 31 60 250 00 4 11 50 90 91 11 No Tip 35 00 277 7...

Page 6: ...ill valve will not shutoff 1 Remove cover and visually check for sliding lever return spring Replace if missing 2 Remove cover and visually check for any tubes rubbing the sliding lever Routing of che...

Page 7: ...Proportioner 8 61 32 AGP 1 GPM Air Gap Proportioner 8 163CHA NB 2 5 GPM Action Gap Proportioner 8 61 45 4 2 5 GPM Air Gap Proportioner 8 61 22 4 4 GPM Action Gap Proportioner 8 61 126AG 4 4 GPM Air G...

Page 8: ...cals corrosion physical abuse or misapplication Rubber and synthetic rubber parts such as O rings diaphragms PVC tubing and gaskets are considered expendable and are not covered under warranty This wa...