Display 
3-3/4  digit  lipuid  cystal  display  from  O  to  approx.3260 
count with decimal point,annunciators display 
Test leads 
Red  test  lead  for  plus  (+)poiarity,Black  test  lead  for 
minus(-) polarity.

 

PREPARATION AND CAUTION BEFORE 

MEASUREMENT 

Before  making  measurements  install  the  batteries
TWO LR-44 batteries can be used.

Avoid  using  the  POCKET  PERSONAL  D.M.M.  in
places  subject  to  high  temperatures,humidity  or
excessive vibration.

Avoid  using  the  POCKET  PERSONAL  D.M.M.  in
places with rapid temperatures varations

If  the  POCKET  PERSONAL  D.M.M.Is  used  near
noise  generating  equipment,be  aware  that  the
display  may  become  unstable  or  indicate  large
errors.

If  the  function  must  be  switch  during  a
measurement  always  remove  the  test  leads  form
the circuit being measured .After measurement, set
the function switch to “OFF”.

MEASURING METHOD 

DC and AC Voltage Measurement

   

(1) 

Set the function switch to “

V”. 

(2)  Connect the test lead to the circuit to be measured, 
the range will change automatically to the level that will 
display the input voltage with the best resolution. 
(3) 

Press  “

SELECT

”  key  to  choose  “

DC

”  or  “

AC

” 

measurement. 
(4)  The  value  indicated  in  the  display  window  is  the 
measured  value  of  voltage  with  proper  decimal  point 
and annunciator indication. 

DC and AC Current Measurement(only2230A) 

1)

Set the selector switch to desired “

mA

” position.

2) Connect the test lead to the circuit to be measured,
the range will change automatically to the level that will 
display the input Current    with the best resolution. 
3) Press  “

SELECT

”  key  to  choose  “

DC

”  or  “

AC

measurement. 
4) The  value  indicated  in  the  display  window  is  the
measured  value  of  Current  with  proper  decimal  point 
and annunciator indication.

 

MEASUREMENT OF RESISTANCE(

Ω)   

(1)

 Set the function switch to 

“Ω”.

 

(2)  Make  sure  all  power  is  OFF  in  the  circuit  to  be 
measured. 
(3) Connect the test leads to the circuit to be measured, 
the range will change automatically, and will Hold on the 
range that will display the measures resistance with the 
best resolution. 
(4)The  value  in  indicatedc  in  the  daisplay  is  the 
measured value of resistance with proper decimal point 
and annunciator indication.

 

Diode Measurement and audible continuity test   

(1)

Set the function switch to “ / ”. 

(2)Connect the test leads to the circuit to be measured . 
Press  “

SELECT

”  key  to  choose  “

”  or  “

” 

measurement. 
(3)Connect  the  test  leads  across  the  diode  under 
measurement,  display  shows  the  approx.  forward 
voltage of this diode. 
  (4) Connect the test leads to two point of circuit, if the 
resistance  is  lower  than 

approx.  20Ω,  the  buzzer 

sounds. 

REPLACEMENT OF BATTERY 

(1)  When  the  batteries  becomes  exhaused  or  drops 
below  the  operating  voltage  voltage  the  “ ”  mark  is 
displayed. 
(2) 

Turn the function switch “OFF” and remove the test 

leads  from  all  test  circuit,prior  to  installing  fresh 
batteries. 
(3)  Remove the batteries by  using the tip of RED test 
probe. 
(4)  Insert the two LR-44 or SR-44 into the battery case 
making sure that proper polarity is observed. 

Caution 

Never  using  the  BLACK  test  probe  to  avoid  the 
short-circuit 

MAINTENANCE 

When making requests for repair services,Please bring 
the instrument directly to the dealer,if this is impossible, 
however,send the instrument directly to our sales office. 
When mailing this instrument,always pack together with 
name  ,address,telephone  unmber  and  the  warranty 
documentation. 

To ensure speedy and reliable repair.always include
information as to the type of faliure and cause.

If  required,always  return  accessories  with  the
instrument.

When  contacting  us,provide  the  medel  number  of
your instrument.