background image

Quick Start Guide

Models 40527, 40527-01

Certified Vaccine PDF Data Logger 

Summary of Contents for FlashLink 40527

Page 1: ...Quick Start Guide Models 40527 40527 01 Certified Vaccine PDF Data Logger ...

Page 2: ...the license document and note the license key number Double click on FlashLink exe and follow instructions in the dialog boxes that appear on the screen When you get to the Enter License dialog box key in the number provided in the license and select Activate The FlashLink shortcut icon will appear on the desktop and system tray Double click the icon to open the program FlashLink Program Manager r...

Page 3: ... in the table of contents or by using the keyword search bar Plug the FlashLink Data Logger into the USB port of the computer select Setup to open the Logger Configuration Wizard The current configuration is displayed Click on Next to access Logging Options and select desired configuration parameters New Configuration window will confirm settings select Next and OK to upload the configuration to t...

Page 4: ...Glycol Bottle This digital data logger DDL features a stainless steel sensor enclosed in a bottle of propylene glycol The cable has a stereo jack for quick disconnect to easily detach the logger and download data The glycol buffered sensor emulates products in the storage unit and keeps the sensor from setting off false alarms due to rapid temperature fluctuations caused by frequent door opening d...

Page 5: ...statistic The LCD automatically reverts to current reading about five seconds after button release and showing a statistic The LCD scrolls through values in this order Maximum temperature Minimum temperature Average temperature If alarms limits are programmed High alarm set point Accumulated time above high alarm if no excursions 00 00 is displayed Low alarm set point Accumulated time below low al...

Page 6: ... reports using its onboard software and saves these files to an internal memory This allows personnel to download and save reports on any PC and does not require FlashLink Program Manager software Option 2 Download data to a PC which is running FlashLink Program Manager software When a data logger is plugged into the USB port the software automatically detects the logger generates and saves Adobe ...

Page 7: ...stops flashing on the LCD Release the buttons and the LCD will flash all icons while it resets When you see a blank screen with first plug the logger back into the glycol bottle sensor connector and then press and hold the START button until the current temperature reading appears on the LCD The logger will now resume recording Remaining Battery Voltage The LCD includes a battery icon to indicate ...

Page 8: ...741 2837 2664 8923 2778 www deltatrakchina com cn DTI China Limited NT Hong Kong 852 3568 5538 www dtiap com DTI Asia Pacific Auckland New Zealand 64 9 5757 886 www deltatraksouthpacific com DTI South Pacific Osaka Japan 81 6 6616 5900 www dtijapan co jp DTI Japan Limited Antwerp Belgium 32 0 3 455 61 25 www deltatrakeurope be DTI Europe bvba DTI South America SA Santiago Chile 562 2758 2866 569 7...

Reviews: