1

 

INTRODUCTION 

TagTemp Stick  is an electronic temperature recorder. A sensor 

measures the temperature and the read value is stored in memory. 

This data can later be downloaded to a computer for display and 

analysis in the form of tables or charts. 
The LogChart II software enables to set up the equipment operation 

mode. It is also used for viewing acquisitions. Other parameters such 

as end of measurements, logging interval, etc., are easily defined 

through the LogChart II software. 
Acquisitions can also be exported to be analyzed in other 

applications, such as spreadsheet programs. 

1.1

 

IDENTIFICATION 

The identification label is on the equipment  body. Check if the 

features described are in accordance with your order. 
Status indicator: This visual indicator reports the status of operation 

of equipment through the number of flashes that occur in an interval 

of five seconds. The states of operation are: 

 

One flash:  The device is waiting to start the log in memory 

(standby) or completed a series of logs in memory; 

 

Two flashes: the device is performing logs in memory; 

 

Three flashes:  the device is or has gone through an alarm 

condition and is not performing logs in memory; 

 

Four flashes:  the device is or has gone through an alarm 

condition and is performing logs in memory. 

 

2

 

TECHNICAL DATA 

Measure Range 

Temperature: –20.0 °C to 70.0 °C.

 

Accuracy 

±

 

0.5 °C @ 25 ºC. 

±

 

1 °C max. along the entire measured range. 

Note: A measure error can be fixed using the 

OFFSET parameter in the LogChart II software.

 

Measurement 

response time (90 %) 

10 min. in air. 

Measurement 

Resolutions 

Temperature: 0.1 °C.

 

Memory capacity 

32.000 (32 k) logs.

 

Measurement 

Interval 

5 seconds min. 
18 hours max.

 

Supply 

3.0 V lithium battery (CR2032), built-in

 

Estimated battery 

autonomy 

 

More than 400 days – Sampling rate of 1 

minute. 

 

More than 500 days – Sampling rate of 30 

minutes. 

Operating 

temperature 

From -20 °C to 70 °C

 

Housing 

Polyamide 

Protection 

Product suitable for applications requiring up to 

IP67  degree of protection. See item "Special 

Care".

 

Dimensions 

78 x 23 x 10 mm

 

Equipment -PC data 

transfer time 

Proportional to the number of records. 20 

seconds to 32.000 records.

 

PC Interface 

Connector USB 

 

LogChart ll software 

operation 

environment 

Configurator software for Windows ® 8, 7 and 

XP. 

Menus in Portuguese, English or Spanish. 

Sets up, reads and displays data on the 

screen.

 

3

 

OPERATION 

It is only possible to operate the equipment  after the LogChart II 

software is installed to a PC, according to the steps described in 

LogChart II  Software  section of this manual. The communication 

between equipment and PC is performed with the aid of the USB-A 

connector. 
The equipment operation mode set up is defined in advance by using 

the  LogChart II  software.  Each setting must be defined and the 

consequences observed. 
The equipment starts and stops logging as defined in settings. 

Summary of Contents for TagTemp Stick

Page 1: ...memory 2 TECHNICAL DATA Measure Range Temperature 20 0 C to 70 0 C Accuracy 0 5 C 25 ºC 1 C max along the entire measured range Note A measure error can be fixed using the OFFSET parameter in the LogChart II software Measurement response time 90 10 min in air Measurement Resolutions Temperature 0 1 C Memory capacity 32 000 32 k logs Measurement Interval 5 seconds min 18 hours max Supply 3 0 V lith...

Page 2: ...nformation Area with information about the equipment such as Model Serial Number equipment Date Time PC Date Time firmware version memory capacity and number of acquisitions stored in memory In this field time is constantly updated while the communication between equipment and computer is taking place 3 Readings Presents a series of parameters that define the acquisition process Interval Defines t...

Page 3: ...Resume button action sends the appropriate command depending on the current registration status If the records are In Progress and pressing this button it will be send a command to Pause the records Pause Pauses the registry allowing it to be resumed later using the Resume button If registration is Paused and pressing this button it will be send a command to Resume the records Resume Resumes the r...

Page 4: ...equipment whose data were just read and its configuration The screen can be displayed by pressing the icon Parameter Viewing Fig 08 General information window 5 3 EXPORTING DATA Logged data can be exported to different file formats for further analysis To export access File Export or click the icon 5 4 EXPORTING THE DATA REGISTERED Battery Level Indicates the level of battery voltage Device Status...

Page 5: ...ected correctly and there is no other program using the same port during communication attempts Make sure there is no physical obstacle blocking the infrared signal Make sure the port selected does not present any problem 7 SPECIAL CARE When handling the device and its battery observe the following To achieve the IP67 protection degree the cover of TagTemp Stick should always be kept properly clos...