background image

Notsi, Ltd., Bulgaria, 9027 Varna, Troleyna 12 street 

Ph.: 00359 899 822010 ; Fax: 00359 52 507227 

Web: 

www.deltapulse.eu

 ; E-mail: 

[email protected]

  

 

Mole Impulse Pro operation manual

 

ground  is  up  to  6  meters.  At  this  depth  is  possible  to  find  out  different  metal 

objects and ammunition. Please, when children work with the detector they must 

be  controlled,  and  the  finds  must  be  dig  out  from  elderly.  The  extraction  of  the 

finds  is  in  whole  at  yours  responsibility.  The  manufacturer  and  the  dealer  have 

not responsibility.  

 

PREPARING FOR OPERATION 

 

It is important to be observed this direction for reaching to the maximal depth 

of  searching.  Go  outside  at  a  place  without  metal  objects,  connect  the  coil  with 

the  device,  and  switch  on  the  POWER  at  position  “1”.  Leave  the  device  to 

operate for about 5 minutes to stabilize his work. Lift out the coil of the searcher 

far away from metal objects. Set the buttons POWER, GAIN, THRESHOLD and 

NOISE at position 10, and the button SIGNAL at position around 

“7”. Take down 

the  coil  to  the  ground  at  20  cm  above  the  surface  and  press  the  button  FAST 

ZERO  for  about  3  seconds.  The  signal  tone  slowly  disappears.  Keep  the  coil 

immovable for several seconds. If you hear a tone, turn the buttons POWER and 

THRESHOLD with one position to the left (9) and if the tone do not longer heard, 

this mean that the device is ready to work. If you hear arbitrary tone, go on once 

more  to  the  left  with  one  position  (8).  When  it  is  necessary  to  throw  off  small 

metal objects like nails, lids, wires and others useless objects, then set the button 

SIGNAL to position from “8” up to “10”. If you want to increase the sensitivity of 

the device at normal soil, in

crease SIGNAL to maximal position of “6-7”. Please 

make a test with SIGNAL to determine the maximal sensitivity. 

 

 

Summary of Contents for Mole Impulse PRO

Page 1: ...pulse eu E mail sales deltapulse eu Mole Impulse Pro operation manual 1 M Mo ol le e I Im mp pu ul ls se e P PR RO O O Op pe er ra at ti io on n m ma an nu ua al l Notsi Ltd Bulgaria 9027 Varna Troley...

Page 2: ...2 QUICK START OPTIMAL POSITIONS POWER NOISE THRESHOLD GAIN move each control slowly to position 10 SIGNAL from position 10 slowly return to a position around 7 The machine is very stable at 10 but th...

Page 3: ...0 Threshold threshold tone in the most cases is at position 8 10 as for soils with humidity above 65 must be above 8 This will be decided in dependency from the situation by the operator Signal elimin...

Page 4: ...bout 5 minutes to stabilize his work Lift out the coil of the searcher far away from metal objects Set the buttons POWER GAIN THRESHOLD and NOISE at position 10 and the button SIGNAL at position aroun...

Page 5: ...ven if you are going many meters Press the button FAST ZERO while you keep the coil immovable above the ground The automatic adjustment will eliminate the parasitic sound For testing of the detector p...

Page 6: ...ed object at depth up to 3 meters When the signal tone rise on an area with big size and after this again slowly fall then you are located big metal object at depth up to 6 meters PREPARING FOR WORKIN...

Page 7: ...ived square and you will found the center of the object If at time of operation you are disturbed from brief sounds from small metal objects on the surface then you must lift up the coil to about 25 c...

Page 8: ...pulse PRO has a possibility to charging of the battery from a car The jack is marked 12V and must be connected to the car s lighter The battery has no automatic switching off at charging from a car bu...

Page 9: ...of dust and then wipe out the panel with a moist soft cotton cloth Keep away the whole device from rain or pouring on liquids If this happens because of carelessness swab up the liquid and do not swit...

Page 10: ...operation Excluded are mechanical damages or caused from wrong use damages At damage during the term of warranty you must send the all device us The charges for sending to Notsi Ltd Bulgaria are at th...

Reviews: