5
VFD-V Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-79
10-18
Loop Speed
a
Factory setting 1.00
Settings
0.00~400.00
Hz
10-19
Loop Point
a
Factory setting 10
Settings
0~20000
10-20
Division (scaling) factor for PG04/05
a
Factory setting 1
Settings
1~128
Parameter 10-20 is used when the drive must follow a second encoder for speed reference.
The main encoder (A) is a factor of the second encoder (B) as follows.
If Pr.10-20 is set to 1, then the feedback from both encoders are 1:1, (1 pulse on encoder A
= one pulse on encoder B). If encoder A is 1 pulse for every 100 pulses on encoder B,
then Pr. 10-20 should be set at 100.
Drawing for position control.
The origin(z phase)
10-16
Orient Speed
10-17
Creep point
10-09
PG Location Control Point
10-19
Loop Point
10-18
Loop Speed
Position control timing:
Master speed
Speed 0
Fwd/Rev
Location control
Location achieve
(Multi-function input)
(Multi-function output
02-01~02-06 set 30
02-11~02-14 set 31
Speed of 10-16
10-17
Creep point
speed of 10-18
10-19
Loop Point
10-09
PG Location
Control Point
10-21
Feed Forward
a
Factory setting 0
Settings
0.0~100.0%
10-22
Position Control Speed Gain
a
Factory setting 100
Settings
0.0~100.0%
Summary of Contents for VFD-V Series
Page 1: ......
Page 2: ...V E 0 5 5011608405 2016 04...
Page 3: ......
Page 7: ......
Page 27: ......
Page 31: ......
Page 115: ......
Page 121: ......
Page 153: ......
Page 159: ...VFD V Series DELTA ELECTRONICS INC ALL RIGHTS RESERVED B 4 Braking Resistors Braking Units...
Page 160: ...B VFD V Series DELTA ELECTRONICS INC ALL RIGHTS RESERVED B 5 Braking Resistors Braking Units...
Page 173: ......
Page 183: ......