Chapter 2 Installation and Wiring
|
VFD-M-D Series
Revision Jan. 2007, MDE2, SW V1.05
2-11
Terminal
Symbol
Terminal Function
Factory Settings
ON: Connect to DCM
RA1
Multi-function Relay1 output
(N.O.) a
RB1
Multi-function Relay1 output
(N.C.) b
RC1
Multi-function Relay1
common
RA2
Multi-function Relay2 output
(N.O.) a
RB2
Multi-function Relay2 output
(N.C.) b
RC2
Multi-function Relay2
common
Resistive Load:
5A(N.O.)/3A(N.C.) 240VAC
5A(N.O.)/3A(N.C.) 24VDC
Inductive Load:
1.5A(N.O.)/0.5A(N.C.) 240VAC
1.5A(N.O.)/0.5A(N.C.) 24VDC
Refer to Pr.6-00 and Pr.6-01 for programming
MO1
Multi-function Output 1
(Photocoupler)
MO2
Multi-function Output 2
(Photocoupler)
Maximum 48VDC, 50mA
Refer to Pr.6-02 to Pr.6-03 for programming
MO1~MO2-DCM
MO1~MO2
MCM
Internal Circuit
Max: 48Vdc
50mA
MCM Multi-function
output
common Common for Multi-function Outputs
Control signal wiring size: 18 AWG (0.75 mm
2
) with shielded wire.