29
ENGLISH
Operation and installation manual SOLIVIA 3.3 EU G3
8.2
Display messages
LED STATUS
DISPLAY
MESSAGE
CAUSE
ELIMINATION
green: <on>
red: <on>
yellow: <on>
-
Display communication
faulty.
- If the fault persists after the device has
been reset, please inform your service
technician.
green: <off>
red: <off>
yellow: <on>
AC frequency
failure
Grid frequency overshoo-
ting or undershooting
specified limit range.
- Check the grid frequency via the display
in the N menu.
green: <off>
red: <off>
yellow: <on>
AC voltage
failure
Grid voltage overshooting
or undershooting specified
limit range.
- Check the grid voltage via the display in
the N menu.
- If no voltage present, check grid auto-
matic circuit breaker.
green: <off>
red: <off>
yellow: <on>
Autotest failed
(only for Italy)
The autotest status is in
error.
Repeat the autotest routine.
green: <flashes>
red: <off>
yellow: <off>
Calibration
ongoing
Check internal settings.
Normal function before input mode.
green: <off>
red: <off>
yellow: <on>
DC injection
failure
DC component of input-
side alternating current is
too high.
- If the fault persists after the device has
been reset, please inform your service
technician.
green: <off>
red: <off>
yellow: <on>
Error # 301
Internal communication
error or hardware fault.
- If the fault persists after the device has
been reset, please inform your service
technician.
green: <off>
red: <off>
yellow: <on>
Error # 302
The device trips and
reverts to grid input mode
once the temperature has
dropped.
- Check the installation site (no direct
sunlight, air circulation).
green: <off>
red: <on>
yellow: <off>
Error # 506
Error # 508
Isolation resistance fault
on the DC side during
start-up phase (# 508) or
running phase (# 506).
- Check the isolation resistance on the DC
side of the PV modules.
green: <on>
red: <on>
yellow: <off>
Isolation start-
up warning
Isolation run-
ning warning
Isolation resistance fault
on the DC side during
start-up phase or running
phase.
- You must check the isolation resistance
on the DC side of the PV modules.
Solar inverter is still feeding!
green: <on>
red: <on>
yellow: <off>
PV+ groun-
ding fault
PV- grounding
fault
Connection PV+ (PV-)
to GND is interrupted or
wrong pole is connected
to GND.
- Check that the GND connection has been
made correctly and/or check the fuse in
the grounding path. Change the fuse if
necessary. The solar inverter remains in
feed-in operation.
green: <off>
red: <off>
yellow: <on>
Relay error
One of the anti-islanding
protection output relays is
faulty / defective.
- The solar inverter is defective.
- Return the device.
green: <off>
red: <off>
yellow: <on>
Revision error
Versions of hard- and soft-
ware are not compatible.
- If the fault persists after the device has
been reset, please inform your service
technician.
green: <on>
red: <on>
yellow: <on>
Self test
ongoing
Initialization of solar inver-
ter on start-up.
The first time the solar inverter is started
up:
- Normal function with a PV cell voltage
of between 100 V and 150 V.
green: <flashes>
red: <off>
yellow: <off>
PV power too
low
Insufficient input power.
- Insufficient insolation (dawn/twilight).
- Check the PV cell voltage via the
display in the N menu.
Summary of Contents for SoLiViA 3.3
Page 1: ...Operation and installation manual for SOLIVIA 3 3 EU G3 3 3 EU...
Page 2: ......
Page 4: ...2 Operation and installation manual SOLIVIA 3 3 EU G3...
Page 39: ...37 ENGLISH Operation and installation manual SOLIVIA 3 3 EU G3...
Page 40: ...38 Bedienungsanleitung SOLIVIA 3 3 EU G3 Bedienungsanleitung SOLIVIA 3 3 EU G3...
Page 42: ...40 Bedienungsanleitung SOLIVIA 3 3 EU G3 Bedienungsanleitung SOLIVIA 3 3 EU G3...
Page 77: ...75 DEUTSCH Bedienungsanleitung SOLIVIA 3 3 EU G3...
Page 78: ...76 Manuale di istruzioni SOLIVIA 3 3 EU G3...
Page 80: ...78 Manuale di istruzioni SOLIVIA 3 3 EU G3...
Page 115: ...113 ITALIANO Manuale di istruzioni SOLIVIA 3 3 EU G3...
Page 153: ...151 FRAN AIS Manuel de fonctionnement et d installation SOLIVIA 3 3 EU G3...
Page 191: ...189 ESPA OL Manual de funcionamiento y de instalaci n SOLIVIA 3 3 EU G3...
Page 192: ...190 Manual de instru es SOLIVIA 3 3 EU G3...
Page 194: ...192 Manual de instru es SOLIVIA 3 3 EU G3...
Page 229: ...227 PORTUGU S Manual de instru es SOLIVIA 3 3 EU G3...
Page 230: ...228 N vod k obsluze SOLIVIA 3 3 EU G3...
Page 232: ...230 N vod k obsluze SOLIVIA 3 3 EU G3...
Page 267: ...265 ESK N vod k obsluze SOLIVIA 3 3 EU G3...
Page 305: ...303 SLOVENSK N vod na prev dzku a in tal ciu SOLIVIA 3 3 EU G3...
Page 306: ...304 Handleiding SOLIVIA 3 3 EU G3 Handleiding SOLIVIA 3 3 EU G3...
Page 308: ...306 Handleiding SOLIVIA 3 3 EU G3 Handleiding SOLIVIA 3 3 EU G3...
Page 343: ...341 NEDERLANDSE Handleiding SOLIVIA 3 3 EU G3...
Page 344: ...342 SOLIVIA 3 3 EU G3...
Page 346: ...344 SOLIVIA 3 3 EU G3...
Page 351: ...349 SOLIVIA 3 3 EU G3 4 3 1 2 DC 3 4 RS485 EIA485 5 6 3 1 2 3 5 6 4...
Page 377: ...375 SOLIVIA 3 3 EU G3 DC 1 2 3 L1 N PE L2 N PE L3 N PE L1 N n PE L2 L3 Solivia 3 3...
Page 380: ...378 SOLIVIA 3 3 EU G3 12 https guarantee solar inverter com SOLIVIA 5 10 5...
Page 381: ...379 SOLIVIA 3 3 EU G3...
Page 382: ...380 Operation and installation manual SOLIVIA 3 3 EU G3 13 Certificates...
Page 383: ...381 Operation and installation manual SOLIVIA 3 3 EU G3...
Page 390: ...388 Operation and installation manual SOLIVIA 3 3 EU G3 Notes...
Page 391: ......