6
Operation and installation manual SOLIVIA 3.3 EU G3
4.2
Technical structure of the solar inverter
A galvanical isolation of the solar inverter from the grid is achieved through a DC/AC converter with
an integrated high-frequency transformer. The photovoltaic voltage is adjusted so that the maximum
power output of the PV modules is also achieved with varying solar irradiation levels and tempera-
tures (MPP-Tracking).
The MPP range of the solar inverter is between 150 V and 450 V. This facilitates the use of PV
modules by a variety of manufacturers. Measures must be taken to ensure that the maximum open-
circuit voltage of 540 VDC is never exceeded. Please note that the maximum open-circuit voltage
will occur at the lowest temperatures anticipated. You will fi nd more detailed information about
temperature dependency in the data sheet of the PV modules. The device’s power consumption is
kept to a minimum.
The high-quality aluminum casing corresponds to protection class IP65 (water-jet-proof and dust-
proof) and is protected against weathering processes by surface refi nement. The cooling charac-
teristic profi le is designed so that operation of the inverter is possible with ambient temperatures
from -25 °C to +70 °C.
A cooling characteristic profi le is used for the removal of the power dissipation caused through the
voltage conversion. An internal temperature control protects the device against excessive tem-
peratures in the interior of the solar inverter. In case of high ambient temperatures, the maximum
transferable power is limited.
The solar inverter is controlled by microcontrollers, which also implement interface communication
and the monitoring of values and messages on the display.
Two independent and redundant microcontrollers control the monitoring of the grid, which is con-
sistent with the feed-in directives of your local utility company and DIN VDE 0126-1-1, EN 50438,
ENEL G.L., RD 1663, RD 661, UTE 15712-1, Synergrid C10/11 and G83/1-1 (anti-islanding protec-
tion). This enables an installation of the solar inverter in the in-house electrical grid.
Operator protection requirements are met by electrically isolating the grid from the PV module. The
electrical isolation between the grid and the PV module is equivalent to basic insulation. Maximum
operator protection is ensured by reinforced isolation between the grid, PV modules and accessible
interfaces (display and RS485 interface). Relevant standards concerning electromagnetic compat-
ibility (EMC) and safety are fulfi lled.
The solar inverter is functional in on-grid operation exclusively. An automated isolation point, which
is approved by a certifi cation agency, guarantees secure disconnection in case of circuit isolation or
interruptions in power supply and avoids isolated operation.
The disconnection equipment allows for automatic isolation for in-plant generation systems of nomi-
nal power ≤ 4.6 kVA, with single-phase parallel feed-in through the solar inverter into the public grid.
Summary of Contents for SoLiViA 3.3
Page 1: ...Operation and installation manual for SOLIVIA 3 3 EU G3 3 3 EU...
Page 2: ......
Page 4: ...2 Operation and installation manual SOLIVIA 3 3 EU G3...
Page 39: ...37 ENGLISH Operation and installation manual SOLIVIA 3 3 EU G3...
Page 40: ...38 Bedienungsanleitung SOLIVIA 3 3 EU G3 Bedienungsanleitung SOLIVIA 3 3 EU G3...
Page 42: ...40 Bedienungsanleitung SOLIVIA 3 3 EU G3 Bedienungsanleitung SOLIVIA 3 3 EU G3...
Page 77: ...75 DEUTSCH Bedienungsanleitung SOLIVIA 3 3 EU G3...
Page 78: ...76 Manuale di istruzioni SOLIVIA 3 3 EU G3...
Page 80: ...78 Manuale di istruzioni SOLIVIA 3 3 EU G3...
Page 115: ...113 ITALIANO Manuale di istruzioni SOLIVIA 3 3 EU G3...
Page 153: ...151 FRAN AIS Manuel de fonctionnement et d installation SOLIVIA 3 3 EU G3...
Page 191: ...189 ESPA OL Manual de funcionamiento y de instalaci n SOLIVIA 3 3 EU G3...
Page 192: ...190 Manual de instru es SOLIVIA 3 3 EU G3...
Page 194: ...192 Manual de instru es SOLIVIA 3 3 EU G3...
Page 229: ...227 PORTUGU S Manual de instru es SOLIVIA 3 3 EU G3...
Page 230: ...228 N vod k obsluze SOLIVIA 3 3 EU G3...
Page 232: ...230 N vod k obsluze SOLIVIA 3 3 EU G3...
Page 267: ...265 ESK N vod k obsluze SOLIVIA 3 3 EU G3...
Page 305: ...303 SLOVENSK N vod na prev dzku a in tal ciu SOLIVIA 3 3 EU G3...
Page 306: ...304 Handleiding SOLIVIA 3 3 EU G3 Handleiding SOLIVIA 3 3 EU G3...
Page 308: ...306 Handleiding SOLIVIA 3 3 EU G3 Handleiding SOLIVIA 3 3 EU G3...
Page 343: ...341 NEDERLANDSE Handleiding SOLIVIA 3 3 EU G3...
Page 344: ...342 SOLIVIA 3 3 EU G3...
Page 346: ...344 SOLIVIA 3 3 EU G3...
Page 351: ...349 SOLIVIA 3 3 EU G3 4 3 1 2 DC 3 4 RS485 EIA485 5 6 3 1 2 3 5 6 4...
Page 377: ...375 SOLIVIA 3 3 EU G3 DC 1 2 3 L1 N PE L2 N PE L3 N PE L1 N n PE L2 L3 Solivia 3 3...
Page 380: ...378 SOLIVIA 3 3 EU G3 12 https guarantee solar inverter com SOLIVIA 5 10 5...
Page 381: ...379 SOLIVIA 3 3 EU G3...
Page 382: ...380 Operation and installation manual SOLIVIA 3 3 EU G3 13 Certificates...
Page 383: ...381 Operation and installation manual SOLIVIA 3 3 EU G3...
Page 390: ...388 Operation and installation manual SOLIVIA 3 3 EU G3 Notes...
Page 391: ......