background image

 

4-2-1. Lock the grille screw (M4×30) into the grille bracket. 

4-2-2. Insert the

 

grille bracket module

 

into the main body, and 

use grille bracket screw (M4×6) to affix the main body. 

 

Insert area

Grille bracket

Grille bracket

screw (M4x6)

4-2-3. Mount the grille onto the main body by using the   

location screw. 

Main body

Grille module

4-2-4. Attach the grille onto the main body by using the grille 

screw and nut,

 

respectively. 

Nut

Grille screw

(M4x30)

 
 

 
 

4-2-5. Install the light bulb and close the lens cover to lock 
into place. 

E12 Lamp (4W Max.)

GU24 Lamp (26W Max.)

Lock lens cover

5. Operation 

CFM

TIME(min)

Delay timer control

(SIG110DL)

or Humidity preset control

(SIG110HL)

Low speed air volume preset control

(SIG110DL, SIG110HL)

SIG110DL

control options

SIG110HL

control options

 

Single Models: SIG80L, SIG110L 

5-1. Single speed control mode: Turn the POWER switch on to 

operate at single speed mode - the LED indicator will be 
green. 

 
Humidity Models: SIG110HL 

5-2. Humidity control mode: Turn the POWER switch on to 

operate at humidity control mode - the LED indicator will 
be blue. When the ambient humidity is higher than the 
user-adjustable set-point, the fan will run at full speed. 
When the ambient humidity is lower than the set-point, 
the fan will continue to run at full speed until a 10- minute 
time delay has elapsed, and then will automatically 
change to the user-adjustable low speed airflow. 

5-3. Full speed mode: Turn the MODE switch on to operate at 

full speed mode - the LED indicator will be amber. 

5-4. Humidity tolerance is about ±10%. As the fan is used 

throughout the years, dust will accumulate periodically. 
This will influence the precision of the humidity detector. 
Readjusting the humidity switch will address this issue. 

Factory setting: low speed airflow 40CFM, humidity 60%RH. 

                                                                                                                   

MODELS  SIG80L / SIG110L / SIG110HL / SIG110DL

4

800

0

CFM

%RH

6

50

90

80

70 0

CFM

TIME(min)

80

40 0

0.5

45

30

15 5

60

CFM

TIME(min)

80

40 0

0.5

45

30

15 5

60

Page 4.

Summary of Contents for SIG80L

Page 1: ...g fire rated construction 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engin...

Page 2: ...stallation 1 Using suspension brackets 1 1 Sliding suspension brackets are available to allow the housing to be positioned between joists up to a span of 24 1 2 Insert the suspension brackets into the channels on the housing Make sure the tabs face up as shown Fig C 1 3 Extend the suspension brackets to fit the width of the joists Hold the fan in place by wrapping the suspension bracket tabs aroun...

Page 3: ...WHITE GROUND bare POWER SWITCH WIRING PLATE LIGHT SWITCH NIGHT LIGHT SWITCH YELLOW RED Humidity Models SIG110HL Dual Speed Models SIG110DL HI POWER SWITCH MODE SWITCH JUNCTION BOX SWITCH BOX WHITE BLACK OFF ON WHITE BLUE GREEN GRD L N L N NIGHT LIGHT SWITCH WHITE YELLOW OFF ON L N LIGHT SWITCH WHITE RED OFF ON L N ON OFF SWITCH purchase separately SWITCH BOX 120 VAC LINE IN WIRING PLATE BLACK WHIT...

Page 4: ...gle speed mode the LED indicator will be green Humidity Models SIG110HL 5 2 Humidity control mode Turn the POWER switch on to operate at humidity control mode the LED indicator will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed When the ambient humidity is lower than the set point the fan will continue to run at full speed until a 10 ...

Page 5: ...Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions 1 During the warranty period a replacement for any defective product will be supplied free of charge for ins...