 PREPARATION

Tools Required for Assembly (not included): Hammer, 

Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, 

Phillips Head Screwdriver, Utility Knife
Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: Turn off electricity at breaker box 

before beginning installation.

Carefully remove unit from carton.
Check area above installation location to be sure that 

wiring can run to the planned location and that duct 

proper ventilation.
Inspect duct work and wiring before proceeding with 

installation.
Before installation, provide inspection and future 

maintenance  access  at  a  location  that  will  not 

interfere with installation work.
You may need the help of a second person to install 

this fan: one person on the attic side and one on the 

room side.

Note: Installations may vary depending on how the 

previous bath fan was installed. Supplies necessary 

for the installation of your bath fan are not all included. 

However,  most  are  available  at  your  local  home 

improvement or hardware store.

Roof cap

(with built-in

damper)

Seal gap

around 

housing

Caulk termination

to duct

Fan housing

Short piece of flexible

duct helps alignment

and absorbs sound

or

Wall cap

(with built-in

damper)

Wall cap

(with built-in

damper)

Proper insulation around the fan to minimize building 
heat loss and gain. 6” circular duct is recommended 
for  installation.  The  ducting  from  this  fan  to  
the outside of building has a strong effect on the 

shortest, straightest duct routing possible for best 
performance,and avoid installing the fan with smaller 
ducts than recommended. Insulation around the ducts 
can reduceenergy loss and inhibit mold growth. Fans 
installed with existing ducts may not achieve their rated 

  )

d

e

ri

u

q

e

r

 t

i

u

c

ri

c

 

d

e

t

c

e

t

o

r

p

-I

C

F

G

(

 

e

v

o

b

a

 t

i

n

u

 

e

t

a

c

o

L

or within 5 feet of the shower head.
Locate unit away from heating or cooling sources 

which can affect humidity levels.
Do not locate near window. Unit may respond to the   

 

    outdoor humidity level.

Unit must be installed in ceiling to properly sense  

 

    moisture.

 

   proper sensing.

For humidity sensing  models only

(SIG80-110H, SIG80-110MH, 

SIG80-110HLED, SIG80-110MHLED)

 

   where the shortest possible duct run and minimum   

   number of elbows will be needed.

Use a roof cap or wall cap that has a built-in damper 

    to reduce backdrafts.

External timer/dimmer switch can be used please  

   contact Delta Breez customer service and consult   

   with a licensed electrician for compatibility .

2~3 ft straight run 

before elbow

Summary of Contents for SIG80-110

Page 1: ...nformation 3 Preparation 4 Wiring Diagrams 5 Assembly Instructions New Construction 6 Assembly Instructions Existing Construction 7 Grille Installation 11 Operation 12 Care and Maintenance 13 Troubles...

Page 2: ...uspension bracket 4 6 to 4 adapter 1 Grille 1 A B X 8 X 4 HARDWARE CONTENTS Images are to scale Long Wood Screw 4 x 25mm Short screw 8 32x1 4 1 2 4 3 SIG80 110 SIG80 110D SIG80 110H SIG80 110MH SIG80...

Page 3: ...e National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into the wall...

Page 4: ...and absorbs sound or Wall cap with built in damper Wall cap with built in damper Proper insulation around the fan to minimize building heat loss and gain 6 circular duct is recommended for installati...

Page 5: ...FF ON L N ON OFF SWITCH purchase separately SWITCH BOX 120 VAC WIRING PLATE BLACK WHITE GROUND bare BLUE MODE SWITCH POWER SWITCH NIGHT LIGHT SWITCH LIGHT SWITCH YELLOW RED Models SIG80 110 SIG80 110M...

Page 6: ...screw 2 For joist spacing 16 in 24 in insert suspension bracket into the bracket cover on the duct connector side and the back of the fan body Install the suspension brackets to the joists with long...

Page 7: ...e outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 5 Punch out Mask from packaging Insert mask and Mask protects unit during construction...

Page 8: ...ng an old fan be sure to cut a 10 1 4 in x 10 1 4 in opening for the fan body Install from below no need for suspension brackets no attic access 4 Remove fan unit by removing 3 screws 5 Remove duct co...

Page 9: ...n wires as shown in the wiring diagram on page 5 14AWG is the smallest conductor that shall box cover 8 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wo...

Page 10: ...t supplied connect house wires to fan wires 5 e g a p n o m a r g a i d g n i r i w e h t n i n w o h s s a cover 3 Connect a 6 in circular duct not supplied and vent to the outside Secure it with duc...

Page 11: ...SIG80 110D SIG80 110H SIG80 110MH Attach grille by pinching mounting springs a and insert into the narrow rectangular slots in fan body a 4 Celling Grille LED light connector Spring Slots Celling Gril...

Page 12: ...will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed and the LED indicator is blue When the ambient humidity is lower than the setpoint th...

Page 13: ...r over 140 Fahrenheit Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Clean the grille in a sink and dry with a cloth 3 Remo...

Page 14: ...oser than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room 1 airfow within r...

Page 15: ...Single Speed 13 Watts 800 Lumens 2700K SIG80 110DLED 120 60 110 9 7 0 48 10 Dual Speed 13 Watts 800 Lumens 2700K SIG80 110HLED 120 60 110 9 7 0 48 10 Humidity Sensor 13 Watts 800 Lumens 2700K SIG80 11...

Page 16: ...liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort...

Reviews: