background image

5

OFF

ON

L

N

POWER SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

GREEN

GRD

BLACK

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WHITE
GROUND

(bare)

POWER

SWITCH

WIRING

PLATE

OFF

ON

L
N

POWER SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

GREEN

GRD

OFF

ON

L

N

NIGHT-LIGHT SWITCH

WHITE

YELLOW

OFF

ON

L

N

LIGHT SWITCH

WHITE

RED

BLACK

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WHITE
GROUND

(bare)

POWER

SWITCH

WIRING

PLATE

LIGHT

SWITCH

NIGHT-

LIGHT

SWITCH

YELLOW

RED

LINE IN

 

HI

POWER SWITCH

MODE SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

OFF

ON

WHITE

BLUE

GREEN

GRD

L

N

L

N

NIGHT-LIGHT SWITCH

WHITE

YELLOW

OFF

ON

L

N

LIGHT SWITCH

WHITE

RED

OFF

ON

L

N

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

WIRING

PLATE

BLACK
WHITE

GROUND

(bare)

BLUE

MODE

SWITCH

POWER

SWITCH

NIGHT-

LIGHT

SWITCH

LIGHT

SWITCH

YELLOW

RED

Models: SIG80-110, SIG80-110MH

Models: SIG80-110HLED, SIG80-110DLED

Model: SIG80-110LED

 WIRING DIAGRAM

BLACK

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WHITE
GROUND

(bare)

POWER

SWITCH

WIRING

PLATE

MODE

SWITCH

NIGHT-

LIGHT

SWITCH

YELLOW

RED

BLUE

HI

POWER SWITCH

MODE SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

OFF

ON

WHITE

BLUE

GREEN

GRD

L
N

L
N

NIGHT-LIGHT SWITCH

WHITE

YELLOW

OFF

ON

L
N

WHITE

RED

Model: SIG80-110MHLED

HI

POWER SWITCH

MODE SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

OFF

ON

WHITE

BLUE

GREEN

GRD

L

N

L

N

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WIRING

PLATE

BLACK
WHITE

GROUND

(bare)

BLUE

MODE

SWITCH

POWER

SWITCH

Models: SIG80-110H, SIG80-110D

Summary of Contents for SIG80-110

Page 1: ...nformation 3 Preparation 4 Wiring Diagrams 5 Assembly Instructions New Construction 6 Assembly Instructions Existing Construction 7 Grille Installation 11 Operation 12 Care and Maintenance 13 Troubles...

Page 2: ...uspension bracket 4 6 to 4 adapter 1 Grille 1 A B X 8 X 4 HARDWARE CONTENTS Images are to scale Long Wood Screw 4 x 25mm Short screw 8 32x1 4 1 2 4 3 SIG80 110 SIG80 110D SIG80 110H SIG80 110MH SIG80...

Page 3: ...e National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into the wall...

Page 4: ...and absorbs sound or Wall cap with built in damper Wall cap with built in damper Proper insulation around the fan to minimize building heat loss and gain 6 circular duct is recommended for installati...

Page 5: ...FF ON L N ON OFF SWITCH purchase separately SWITCH BOX 120 VAC WIRING PLATE BLACK WHITE GROUND bare BLUE MODE SWITCH POWER SWITCH NIGHT LIGHT SWITCH LIGHT SWITCH YELLOW RED Models SIG80 110 SIG80 110M...

Page 6: ...screw 2 For joist spacing 16 in 24 in insert suspension bracket into the bracket cover on the duct connector side and the back of the fan body Install the suspension brackets to the joists with long...

Page 7: ...e outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 5 Punch out Mask from packaging Insert mask and Mask protects unit during construction...

Page 8: ...ng an old fan be sure to cut a 10 1 4 in x 10 1 4 in opening for the fan body Install from below no need for suspension brackets no attic access 4 Remove fan unit by removing 3 screws 5 Remove duct co...

Page 9: ...n wires as shown in the wiring diagram on page 5 14AWG is the smallest conductor that shall box cover 8 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wo...

Page 10: ...t supplied connect house wires to fan wires 5 e g a p n o m a r g a i d g n i r i w e h t n i n w o h s s a cover 3 Connect a 6 in circular duct not supplied and vent to the outside Secure it with duc...

Page 11: ...SIG80 110D SIG80 110H SIG80 110MH Attach grille by pinching mounting springs a and insert into the narrow rectangular slots in fan body a 4 Celling Grille LED light connector Spring Slots Celling Gril...

Page 12: ...will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed and the LED indicator is blue When the ambient humidity is lower than the setpoint th...

Page 13: ...r over 140 Fahrenheit Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Clean the grille in a sink and dry with a cloth 3 Remo...

Page 14: ...oser than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room 1 airfow within r...

Page 15: ...Single Speed 13 Watts 800 Lumens 2700K SIG80 110DLED 120 60 110 9 7 0 48 10 Dual Speed 13 Watts 800 Lumens 2700K SIG80 110HLED 120 60 110 9 7 0 48 10 Humidity Sensor 13 Watts 800 Lumens 2700K SIG80 11...

Page 16: ...liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort...