background image

The power behind competitiveness

Delta Power Monitor

Installation Manual
R3E 

(for commercial use only.)

www.deltaww.com

 

Summary of Contents for R3E

Page 1: ...The power behind competitiveness Delta Power Monitor Installation Manual R3E for commercial use only www deltaww com...

Page 2: ...Communications Unit Setting Power Monitor and Cable Default Settings Connection Installation Method Wall Installation Desktop Installation Wiring access Description of the screen display Home Screen O...

Page 3: ...d in some cases may also result in serious injury or death Failing to handle the Product properly may result in the described danger leading to slight or intermediate level injuries or property damage...

Page 4: ...Product in the following types of locations There is danger of burnout in some rare cases Locations that are exposed to rain water such as outdoors or under eaves and the like Locations that are expos...

Page 5: ...t is prevented from having air flow such as inside closets or under stairs 4 Install the Product with the DELTA logo facing up when installing the Power Monitor on a wall When not installed on a wall...

Page 6: ...terval into the past will result in the loss of performance data Set the date and time correctly Example A case where performance data is lost The time is inadvertently changed from 9 15 to 8 45 and t...

Page 7: ...ng the operating temperature range 20 to 50 C Do not install above 2000m MSL or higher Do not expose to water vapor oil vapor smoke cotton dust metal powder sawdust Warakuzu 7 Store the Product in a l...

Page 8: ...e 2 pieces Product name Power Monitor Wall Surface Desktop Mounting Plate Wood screws for Wall Surface Desktop Mounting Plate dia 4 x 20 mm Shape Qty Remarks This is a plate used to install the Produc...

Page 9: ...9 190mm 120mm 32mm 25mm 35mm 58mm 40mm 7 inch Power Monitor Wall Surface Desktop Mounting Plate POWER MONITOR 1 2 Dimension Preparation before construction...

Page 10: ...ed to procure their own USB memory and USB cable Insertion slot for anchoring the Wall Surface Mounting Plate This is the insertion slot used to install the Wall Surface Desktop Mounting Plate when in...

Page 11: ...tion 2 1 Installation order Setting One Point Please set connection ID before connect to the Inverters The ID of inverters must be different The ID range is 1 32 Default Settings Installation Method I...

Page 12: ...odel please check the inverter Operation and Installation Manuals PV Panel Inverter Inverter 2 Inverter 3 Power Monitor Communication connector Communication connector Distribution box Switchboard The...

Page 13: ...ave been inserted securely Cables Make sure to use RS 485 cables Prepare 0 3 to 0 5mm2 x single wire 4 cores twin wires rather than 2 pair shielded cables rated temperature 80 C to 85 C Read the inver...

Page 14: ...e range of Power Monitor is 10Vdc 16Vdc and rated operating voltage is 12Vdc Distance limitation The power line between monitor and inverter is max 100m and the communication line between monitor and...

Page 15: ...in connector into the main unit Pass a screwdriver through the screw hole and tighten the two screws for the 6 pin connector When all the wiring is complete install the Power Monitor in its installati...

Page 16: ...fault Settings 4 1 Connection connection setting start screen Time settings screen Date and time shown are examples After started up please choose language Language selection screen When monitor shows...

Page 17: ...ation dialog box will be displayed Touch the Yes button once again Time change dialog box Time change confirmation dialog box 17 Select the date frame The date selection screen will be displayed Selec...

Page 18: ...ed immediately after the settings are made a icon is displayed so check the following details 1 to 3 mins later Check that the icon is not displayed on the home screen Check that the values for the po...

Page 19: ...location where the provided wood screws cannot be used Apply torque of 1 5 to 2 0 Nm when installing wood screws on a wall made of wooden materials Install on a flat wall surface Verify the hooking po...

Page 20: ...ccess Remove the tab on the wiring access using a pair of pliers or the similar tool Remove burr with a pair of pliers to ensure that the cables are not scratched Pass a screwdriver through the screw...

Page 21: ...cessful Internet time synchronization is successful Suppression icon A Suppression icon is displayed when there is suppression on the operation of the Inverter Icon Operating mode Voltage elevation su...

Page 22: ...or icon An error icon is displayed to indicate that one or more errors are occurring The Error icon is ordinarily not displayed and is displayed when one or more errors occur Refer to 8 When Something...

Page 23: ...Thus the numerical values that are displayed do not necessarily completely match with the true value in some cases as described above Refer to 8 When Something Seems Wrong Troubleshooting Page 40 for...

Page 24: ...the Inverter are unable to communicate with each other Screens indicated with solid lines are displayed for ordinary operations The screens in gray are displayed when operating in service mode Power t...

Page 25: ...object with a slender tip into the reset hole on the base of the unit to push the reset button The device will be reset Restart the Power Monitor The settings and records will not be deleted 25 POWER...

Page 26: ...ce Mode Service mode is a hidden mode for installer Please do not tell any customer the procedure of entering service mode Touch the home screen in the following order to enter service mode Procedure...

Page 27: ...ecessary to switch to service mode to make the connection setting The connection setting page is not displayed in normal mode Expanding the inverters If expanding the solar generator system and adding...

Page 28: ...amount of power generated by the additional inverters cannot be measured unless the following settings are made 1 Reset and clear all the inverter data See the inverter Operation and Installation Man...

Page 29: ...h the button to display the inverter selection dialog box and then touch the number of the inverter that you want to view Updates the settings for the selected inverter Updates the settings for all th...

Page 30: ...frame for the time The time selection screen will be displayed Select the time that you want to set Touch the button on the time selection screen The time change dialog box will be displayed Check the...

Page 31: ...nchronization Time Zone Choose time zone Period Choose interval between each time synchronization The time change dialog box will disappear and the time change confirmation dialog box will be displaye...

Page 32: ...occurring the screen is turned on and the display reverts to the Home screen Screen Brightness The brightness of the screen can be selected in ten levels Setting range 1 2 3 4 5 6 7 8 9 10 The defaul...

Page 33: ...ed None of the settings will change until the Save button is touched at the end Caution is required Touch to turn off the dialog box Screen Change dialog box Touch and then on the home screen Operatin...

Page 34: ...Other Devices Pyrheliometer Thermometer can be set on this page Touch and choose DEA485 to enable pyrheliometer thermometer ID range is 41 50 Touch to set and touch to close dialog 34 Service Mode...

Page 35: ...manual of devices before setting and ask manufacturer if any question Modbus Sensor Box Pyrheliometer thermometer RS 485 Connection example Power Monitor 6 pin Connector Communications Connector Termi...

Page 36: ...o the Power Monitor Not displayed in normal mode For maintenance by Delta For maintenance by Delta You can back up the data of the Power Monitor to USB Restores the backup data from USB to the Power M...

Page 37: ...on page is unnecessary to set It is used to connect other devices by Ethernet Internet setting for the Power Monitor Need some knowledge of network management to setting are protocols for other indust...

Page 38: ...nes the number of bits is used in the network address from the IP address header Gateway IP Set gateway device IP to access internet DNS Domain Name Server which manages the corresponding relationship...

Page 39: ...ppression screen Change the display to the previous month Change the display to the next month Suppression record That displays the set of suppression details Touch on the desired date to display the...

Page 40: ...Operating mode Description Error icon An error icon is displayed to indicate that one or more errors are occurring The Error icon is ordinarily not displayed and displayed when one or more errors occu...

Page 41: ...when the system is not restored for a long period of time Suppression icon Displayed when the Inverter is being suppressed Icon Operating mode Voltage elevation suppression Temperature elevation supp...

Page 42: ...should be taken in cases where the following symptoms occur are described Voltage elevation suppression and temperature elevation suppression are displayed Verify the frequency and duration of occurr...

Page 43: ...ns 120 H x 190 W x 32 D mm Weight 440 g Displayed details Power generation calendar history Inverter information error log De rating Log display and the like Maximum power consumption 10 W or less inc...

Page 44: ......

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...20170113...

Reviews: