background image

LTL3000 User Manual / June 2020 

22

 

DELTA 

For your safety 

Read all instructions. Failure to follow all instructions listed below may result in electrical shock, fire and/or 
serious injury. 

 

The battery and the charger are specifically designed for use in conjunction with one another. 
Charging should be done only with the charger delivered with the instrument. 

 

Protect the battery from rain and moisture. The penetration of water in a battery charger increases 
the risk of electric shock. 

 

Do not insert battery pack in charger if battery is cracked. Using damaged battery may result in 
electric shock or fire. 

 

Do not disassemble charger or operate the charger if it has received a sharp blow, been dropped or 
otherwise damaged in anyway. Incorrect reassembly or damage may result in electric shock or fire. 

 

Keep the battery charger clean. Contamination may cause the danger of electric shock. 

 

Check the battery charger, cable and plug each time before using. Do not use the battery charger 
when defects are detected. Do not open the battery charger yourself and have it repaired only by 
qualified personnel using original spare parts. Damaged battery chargers, cables and plugs increase 
the risk of electric shock. 

 

Do not operate the battery charger on easily inflammable surfaces (e.g. paper, textiles, etc.) or 
combustible environments. There is danger of fire due to the heating of the battery charger during 
charging. 

 

Do not store battery in charger. Storing the battery in the charger over a long period of time could 
lead to battery damage and fire. 

 

See further details in the charger user guide. 

 
Practical advice 

With continuous or repetitive charging cycles without interruption, the charger can warm up. This is of no 
consideration and does not indicate a technical defect of the unit. 

 

USB connection 

The LTL3000 is featured with an USB port for connection to a USB memory stick, when you want to transfer 
measurement data. The USB port is placed on the side of the instrument above the battery slot.  

Only use a FAT32-formated USB memory stick. Other file formats are not supported. If your USB stick is not 
working, reformat it and select 

‘FAT32’ as file system. 

 

Summary of Contents for LTL3000

Page 1: ...DELTA Venlighedsvej 4 DK 2970 H rsholm Denmark Tel 45 43 25 14 00 roadsensors delta dk LTL3000 Retroreflectometer User Manual June 2020 English language version...

Page 2: ...e or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different fr...

Page 3: ...UPON REQUEST Intended use purpose LTL3000 retroreflectometer is a portable field instrument used for on site inspection and quality control of retroreflection properties of road markings Important Sa...

Page 4: ...LTL3000 User Manual June 2020 4 DELTA...

Page 5: ...LTL3000 User Manual June 2020 5 DELTA...

Page 6: ...LTL3000 User Manual June 2020 6 DELTA...

Page 7: ...measurement 12 Series 13 Users 14 Log 15 Calibration 16 Settings 19 Battery 20 Battery charger 21 USB connection 22 Maintenance 23 Appendix A Specifications 25 General characteristics 25 Electrical c...

Page 8: ...and standards can be found on https roadsensors madebydelta com LTL3000 measures RL nighttime visibility and Qd daytime visibility under dry and wet conditions LTL3000 measures RL from 0 to 4000 mcd...

Page 9: ...00 instrument After 10 15 seconds the system has booted and the instrument is ready for use Stand by the LTL3000 automatically switches to stand by mode if the instrument has not been used for a speci...

Page 10: ...the top of the display screen give you information about the instrument status and operational mode Icon explanation The current time hour min USB drive is connected and accepted GNSS signal is activ...

Page 11: ...e menu again just touch the display or press X on the instrument handle The main menu consists of these elements Icon Function Explanation Measure Perform an inspection Series Select add edit or delet...

Page 12: ...u want to measure and press the green button on the instrument handle Wait a second until the reading is shown on the display The measurement data is automatically saved by the LTL3000 instrument You...

Page 13: ...new series and write a name in the Name field for your new series use the keyboard on the touch screen Press the return arrow to finish The series is now added and you can continue with your measurem...

Page 14: ...be linked to the data Add a new user Press on the top bar to add a new user Type the name of the new user in the Name field by using the keyboard on the touch screen Press the return arrow to finish...

Page 15: ...measurements in the series Avg an average of all the measurements in the series Max the highest value measured in the series Min the lowest value measured in the series Export measurement data Series...

Page 16: ...in the morning before commencing your measurements The calibration process automatically compensates for instrument offsets etc It is possible to make three different types of calibrations Reference R...

Page 17: ...k calibration To do a dark calibration follow these steps Select Calibrate from the main menu Press RL Dark calibration on the screen Tilt the instrument backwards and make sure it is not pointing at...

Page 18: ...ill warn about this fact before calibration Note Be aware that it is NOT possible to recover the factory calibration if the Qd value is recalibrated Normally it is sufficient to make a reference calib...

Page 19: ...LTL3000 User Manual June 2020 19 DELTA Settings To adjust the regional settings and time date select Settings from the main menu...

Page 20: ...urements on a fully charged battery indicates that the battery is worn out and must be replaced Insert the rechargeable battery on the side of the LTL3000 For your safety Do not expose the battery to...

Page 21: ...een indicator light is on the charger is plugged in but the battery is not inserted or the battery is fully charged and is being trickle charged If the green indicator light is flashing the battery is...

Page 22: ...charger when defects are detected Do not open the battery charger yourself and have it repaired only by qualified personnel using original spare parts Damaged battery chargers cables and plugs increas...

Page 23: ...not properly turned off it will deplete the battery during storage You may clean the LTL3000 instrument and the touch screen using a soft clean linen cloth with mild detergent Battery A substantial dr...

Page 24: ...etroreflectometer is correct it is important that the surface on the calibration target is clean and undamaged Be careful not to touch the calibration target white side When not in use keep the calibr...

Page 25: ...ion angular spread 0 17 Type 30m CEN Illumination angular spread horizontal 0 33 Illumination angular spread vertical 0 17 Field of measurement Width 50 mm 2 inch Length typ 180 mm 7 1 inch RL range m...

Page 26: ...pprox 1 hour 15 minutes Other Data memory 8 GB Data transfer USB memory stick Environmental specifications Operation temperature 0 C to 60 C 32 F to 140 F Storage temperature 10 C to 60 C 14 F to 140...

Page 27: ...020 27 DELTA Regulatory compliance EU Radio EN 303 413 V1 1 1 2017 EMC EN 301 489 19 V2 1 1 2019 04 Safety IEC 61010 1 2010 AMD1 2016 EN 61010 1 2010 A1 2019 USA EMC FCC 47 CFR Part 15B class B Canada...

Page 28: ...sed on the LTL3000 equipment CE mark indicates conformance with the essential requirements of the directive Dispose of the instrument in compliance with local regulations for the disposal of electroni...

Page 29: ...instrument is delivered with the below items 1 Carrying case 2 LTL3000 instrument including battery 3 Battery charger 4 Spare battery 5 USB stick for data transfer 6 User manual on USB stick 7 Calibra...

Reviews: