background image

Make sure that all wiring is secured, the specified wires are used, and there is no strain on the terminal 

connections or wires. 

3. 

If refrigerant gas leaks during installation, ventilate the area immediately. Do not directly touch refrigerant 

that has leaked from refrigerant pipes or other areas, as there is a danger of frostbite. 

4. 

Before serving or cleaning unit, switch power off and disconnect power supply. 

5. 

When cutting or drilling into wall or ceiling, do not damage electrical wiring or hidden utilities. 

6. 

Be sure to use only the specified accessories and parts for installation work. 

7. 

This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, 

or for commercial use by lay persons”

.

 

 

  Caution 

1.  Install the HEX on a wall/ door strong enough to withstand the weight of the unit. 

2.  Do not allow a child to mount on the outdoor unit or avoid placing any object on it. 

3.  Do not block air inlets or exits. 

4.  Do not install the HEX at any place where there is a danger or flammable gas leakage. 

5.  To avoid injury, do not touch the air inlet or aluminum fins of unit. 

6.  Watch your steps at the time of fin cleaning or HEX inspection. 

7.  Do not topple the HEX while moving or storage. 

8.  The appliance is not to be used by persons (including children) with reduced physical, sensory or mental 

capabilities,  or  lack  of  experience  and  knowledge,  unless  they  have  been  given  supervision  or 

instruction. 

9.  Children being supervised not to play with the appliance. 

 

Summary of Contents for HEX180PB

Page 1: ...PB Rev 00 Sample Date Code Sample Issue Date Mar 21 2018 Delta Electronics Inc 252 Shang Ying Road Kuei San District TEL 886 0 3 3591968 Taoyuan City 33341 Taiwan R O C FAX 886 0 3 3591991 Please send...

Page 2: ...ermal and Airflow 4 2 Electrical Specification 4 2 1 Indicator Connector 4 2 1 1 Power Supply Alarm Connector 4 2 1 2 Panel Operation 5 2 2 Fan Control Curve 5 3 Environmental Condition 6 3 1 Operatin...

Page 3: ...HEX unit and be sure to install it correctly After completing the installation make sure that the unit operates properly during the start up operation Meaning of WARNING and CAUTION notices Warning Fa...

Page 4: ...rained users in shops in light industry and on farms or for commercial use by lay persons Caution 1 Install the HEX on a wall door strong enough to withstand the weight of the unit 2 Do not allow a ch...

Page 5: ...Specification for Approval Customer Description Heat Exchanger Customer P N Rev Delta model no HEX180PB Rev 00 Sample revision Date Code Sample issue date Quantity INTERNAL EXTERNAL...

Page 6: ...ght Kg 25 0 Mounting Method N A Door Side Color optional N A RAL7035 Environmental Protection Performance Operating Temperature Range C 20 to 65 Refrigerant type and quantity N A R134a 350 10g Protect...

Page 7: ...Page 2 1 3 Dimension 1 Material steel sheet SGCC t 1 0mm 2 Finish Powder coating 75 m MIN Color RAL 7035 3 Dimensional Tolerance 1 0mm 0 04 1 4 Mounting Panel Cutout...

Page 8: ...ease do not use strong water jet to impact the center of fan and the surface of condenser The bottom hole of the heat exchangers is used for drainage please clear drain holes when the maintenance Plea...

Page 9: ...eparated mechanism design internal and external air flow won t be mixed since the waste heat can be dissipated from the cabinet to the ambience Internal temperature sensor is placed at return air stre...

Page 10: ...3 Pin 4 Pin 5 Pin 4 Control board NTC and fan are in normal status OPEN CLOSE Power off or control board is disabled CLOSE OPEN NTC resistance is over range such as open circuit or short circuit or O...

Page 11: ...expected to be at least 100 000 hours continuous operation at 35 C with 15 65 RH label rated voltage 4 Reliability Table Test item Condition High temperature IEC 60068 2 2 Low temperature IEC 60068 2...

Page 12: ...Notice Check the surrounding obstacles to make sure the product get enough space for air circulate Pin Description Cable wire size 1 48V 16 AWG 2 0V 16 AWG 3 Normal open 24 AWG 4 Common 24 AWG 5 Norm...

Page 13: ...and humidity range as indicated in the Delta product Specification s and product Instruction User Manual s Filters if applicable must be cleaned regularly Products and any parts thereof must not be mo...

Page 14: ...utside of the carton Delta Electronics Inc is not responsible for material damaged in transit Shipping cost for all non warranty repairs is the responsibility of the sender and must be shipped prepaid...

Reviews: