3. CONNECT WIRING
3-1. Follow all local electrical and safety codes, ANSI/NFPA70.
3-2. NEVER place a switch where it can be reached from a tub or
shower.
3-3.
Connect wires as shown in wiring diagrams.
Models: GBR80HL, GBR100HL
Models: GBR80MHL, GBR100MHL
SWITCH BOX
3-4. Using wire nuts (not provided), connect house power cable to
ventilating fan.
3-5. 14 AWG (2.1 mm
2
) is the smallest conductor that shall be used
for branch-circuit wiring.
4. GRILLE ATTACHMENT & TEST RUN
4-1. Insert the grille bracket into the main body, and lock screw
(M4×6) to fix on the main body.
4-2. Insert the light plug connector into the housing.
4-3. Insert the motion plug connector into the housing. (only for
GBR80MHL and GBR100MHL)
4-4.
Mount the grille to the grille bracket by screw
(#8-32 × 1-1/4”).
4-5. Install light bulbs and attach the cover.
GU24 Lamp(26W Max.)
#8-32 x 1-1/4"
Diameter: #8
Thread count: 32
Length: 1-1/4”
Screw
Lock Lens cover
4-6. When the power on, check for abnormal vibration or sound.
Screw M4 x 6