INSTALLATION AND OPERATING INSTRUCTIONS 

VENTILATION FAN / LIGHT 

  READ AND SAVE THESE INSTRUCTIONS 

  GENERAL SAFETY INFORMATION 

1.

Make sure that the electric service supply voltage is AC 120V, 

60Hz. 

2.

Follow all local electrical and safety codes, as well as the Nation 

Electrical Code (NEC) and the Occupation Safety and Healthy Act 

(OSH Act). 

3.

Always disconnect the power source before working on or near 

the ventilating fan, motor or junction box. 

4.

Protect the power cord from sharp edges, oil, grease, hot 

surfaces, chemicals or other objects. 

5.

Do not kink the power cord. 

6.

Do not install the unit where ducts are configured as shown in 

Fig. A. 

7.

Provide suction parts with proper ventilation. 

8.

This unit is UL listed for use over a bathtub or shower when 

installed in a GFCI protected branch circuit.

 

9.

These ventilating fans are intended for residential usage only.

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

1.

Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer. 

2.

Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel. 

3.

Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction. 

4.

Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to 
prevent back drafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE) and the local code authorities. 

5.

When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities. 

6.

Ducted fans must always be vented to the outdoors. 

7.

If this unit is to be installed over a tub or shower, it must be 

marked as appropriate for the application and be connected to a 

GFCI (Ground Fault Circuit Interrupter) – protected

 

branch 

circuit. 

8.

Do not use this unit with any other solid-state control devices. 

Solid-state control devices may cause harmonic distortion, 
which can cause a motor humming noise. 

9.

NEVER place a switch where it can be reached from a tub or 

shower. 

10.

Not to be installed in a ceiling thermally insulated to a value 
greater than R40. (This is required for installation in Canada 

only).

 

 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

 

Fig. A 

CAUTION

1.

For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors. 

2.

Not for use in cooking areas. (Fig. B) 

3.

This product must properly connect to the grounding conductor 

of the supply circuit. 

4.

To reduce the risk of injury to persons, install the fan at least 8.2 

feet (2.5m) above the floor.

 

Cooking area

Do not install above or

  inside this area

 Cooking

Equipment

Floor

 

Fig. B 

 
 

45°

45°

Page 1.

MODELS  GBR

80HL / GBR80MHL

Summary of Contents for GBR80HL

Page 1: ... fire rated construction 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engine...

Page 2: ...nsion brackets into the channels on housing Make sure tabs face up shown 1 4 Extend suspension brackets to the width of the joists Hold fan in place with the suspension brackets tabs wrapping around the bottom of joist 1 5 Fasten suspension brackets to joists with nails or screws through holes near nails 1 6 Secure suspension brackets together with screws 2 DUCT CONNECTION 2 1 Insert the duct into...

Page 3: ...llest conductor that shall be used for branch circuit wiring 4 GRILLE ATTACHMENT TEST RUN 4 1 Insert the grille bracket into the main body and lock screw M4 6 to fix on the main body 4 2 Insert the light plug connector into the housing 4 3 Insert the motion plug connector into the housing only for GBR80MHL and GBR100MHL 4 4 Mount the grille to the grille bracket by screw 8 32 1 1 4 4 5 Install lig...

Page 4: ... 14 2 100 Full speed 5 6 60 Low speed Note Design and specifications subject to change without notice DIMENSIONS WARRANTY cloth RH 50 5 0 0 6 0 7 0 8 0 CFM RH 50 6 0 0 6 0 7 0 8 0 CFM DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in materi...