background image

 

 

DOP-107H 

High color

Controllable

User-friendly 

Delta Electronics Inc, 

No.18, Xinglong Rd., Taoyuan City 

33068, Taiwan 

Instruction Sheet

 

(1) General precautions 

Thank you for purchasing this product. This DOP-107H instruction sheet provides information for the DOP-107H series 
HMI. Before using this product, read through this instruction sheet carefully to ensure the correct use of the product. 
Keep this sheet handy for quick reference whenever needed. Before finishing reading this sheet, follow the following 
instructions. 

 

Install the product in an indoor environment which is free of vapor, corrosive and inflammable gas. 

 

Refer to the wiring diagram when connecting the wires. 

 

Ensure this product is correctly grounded. The grounding method must comply with the national standard 
guidelines (refer to NFPA 70: National Electrical Code, 2005 Ed.

)

 

Do not change the wiring when power is on. 

 

Do not touch the power supply when power is on, or it may cause electric shock. 

 

When the HMI displays a low power notification and requires a battery change, contact the local distributor or 
Delta Customer Service Center for the replacement. Do not change the batteries by yourself. 

If you have any inquiry during operation, contact the local distributors or Delta Customer Service Center. The instruction 
sheet may be revised without prior notice. Contact our distributors or download the latest version from the Delta website 
(

http://www.deltaww.com

). 

 

(2) Safety precautions 

Pay attention to the following safety precautions during installation, wiring, operation, maintenance, and inspection. 

Installation 

 

 

Comply with the instructions specified in the user manual for installation, or it may cause damage to 
the equipment. 

 

Avoid exposing the product to an environment containing vapor, corrosive gas, inflammable gas, or 
other foreign matter, or it may cause product damage, electric shock, fire, or explosion. 

 

Do not install the HMI in an environment where the ambient temperature exceeds the specified 
range, or it may cause abnormal operation or product damage.   

 

This product has the approval of KC Class A (for commercial devices), which is designed for 
commercial or industrial use, rather than for domestic use. If you have unintentionally purchased or 
sold the HMI products, replace them with products having the approval of KC Class B (for domestic 
use). 

 

Do not install the HMI to the machinery that may cause personnel injury, equipment damage, or 
emergency stop. 

Wiring 

 

 

Connect the ground terminals to class-3 ground system. Ground resistance should not exceed 100Ω. 
Improper grounding may cause communication error, electric shock, or fire. 

 

Do not connect other wire rods to extend the cable length, or it may cause poor communication or 
malfunction.   

Operation 

 

 

Program the HMI screens with the DOPSoft software. If the HMI is not well-programmed, it may 
cause abnormal operation. To avoid personnel injury or equipment damage during operation, ensure 
the communication error occurring between the HMI and controller or equipment does not cause 
malfunction when programming the HMI screens. 

 

Back up the programmed HMI screens and programs to avoid unexpected data loss.   

 

Place the HMI on a flat surface or hang it with the hook on its back to prevent it from falling and thus 
crashing.   

 

 

 

Do not change the wiring when power is on, or it may cause electric shock or personnel injury. 

 

Do not touch the panel with sharp objects, or it may make a dent in the panel, resulting abnormal 
operation of the HMI. 

Maintenance and inspection 

 

 

Do not touch the internal parts of the HMI, or it may cause electric shock or product damage. 

 

Do not touch the wiring terminals within 10 minutes after turning off the power. The residual voltage 
may cause electric shock. 

Wiring method 

 

 

The voltage applied to the HMI should not exceed the specified range, or it may cause product 
damage, electric shock, or fire.   

 

If any cable removal is forced, check the connection again before resuming the operation. 

Communication wiring 

 

 

Ensure the ground circuit is correct to avoid poor communication. 

 

To prevent excessive interference from causing abnormal operation of the HMI, place the 
communication cable, all power cables, and the motor power cable in separate conduits. 

 
 
 
 
 
 
 
 

 
(3) Model explanation 

 (1)   

DOP

 (2)   

1

 (3)   

07

 (4)   

HS

 (5)   

4

 (6)   

6

 (7)   

5

 (8)   

ZM

 

(1) 

Product name 

DOP: Delta Operation Panel (HMI) 

(2) 

Series 

1: 100 series HMI 

(3) 

Panel size 

07: 7.0" 

 

(4) 

Type 

HE: Ethernet 
HS: standard 

(5) 

Display 

resolution 

4: WVGA 

(6) 

External device 

Code 

MPG 

SD 

15 Keys 

21 Keys 

 

 

 

 

 

 

 

 

 

 

 

 

 

(7) 

Cable length 

5: 5 m 
A: 10 m 

(8) 

Connector 

ZM / ZD: D-SUB connector 

 

(4) Description of each part 

  DOP-107HE42x / DOP-107HE46x / DOP-107HS42x / DOP-107HS46x (front view) 

 

DOP-107HE42xZM / DOP-107HE46xZM (front view) 

 

DOP-107HE47xZD (front view) 

 

Power indicator 

Auxiliary keyboard 

Emergency stop switch 

Operation / display area 

MPG 

 

 

 

DOP-107HE42x /DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / /DOP-107HE47xZD / DOP-107HS42x / 
DOP-107HS46x (rear view) 

 

3-position operation switch 

Bus 

 

DOP-107HE42x / DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / DOP-107HE47xZD / DOP-107HS42x / 
DOP-107HS46x (bottom view) 

 

 

 

USB slave 

SD card 

 

(5) Installation environment 

Before installation, this product must be kept in the shipping carton. In order to retain the warranty coverage and for 
maintenance, follow the following instructions for storage. While the product is temporarily not in use: 

 

Store the product in a dust-free and dry place. 

 

Store the product in an ambient temperature of -10°C to +60°C (14°F to 140°F). 

 

Store the product in a relative humidity range of 10% to 90% RH (non-condensing). 

 

Avoid storing the product in an environment containing corrosive gas and liquids. 

 

Properly wrap the product and place it on a shelf or platform. 

 

The suitable installation environment should be a location that is free of devices that generate excessive heat, 
water, vapor, dust and oily dust, corrosive and inflammable gas and liquids, airborne dust and metal particles, 
vibration, and electronic interference. 

 

This product must be used at an altitude below 2,000 m (6,561.68 feet). 

 
(6) Wiring 

D-SUB connector 

 

Pin assignment for DOP-107HE42xZM / DOP-107HE46xZM / DOP-107HE47xZD series (D-SUB)

 

25-pin D-SUB 

Function 

LAN RD+ 

LAN RD- 

Reserved 

Emergency stop –

 

NO(A)   

Emergency stop –

 

NO(A) 

Emergency stop –

 

NC(B) 

10 

Emergency stop –

 

NC(B) 

13 

0Vdc input (use SELV power supply, isolated from MAINS by double insulation) 

14 

LAN TD+   

15 

LAN TD- 

18 

external power input of MPG 

20 

output point A of MPG 

21 

output point B of MPG 

22 

3-position operation switch –

 

NO(A) 

23 

3-position operation switch –

 

NO(A) 

25 

24Vdc input (use SELV power supply, isolated from MAINS by double insulation) 

 

Summary of Contents for DOP-107H Series

Page 1: ... with the hook on its back to prevent it from falling and thus crashing Do not change the wiring when power is on or it may cause electric shock or personnel injury Do not touch the panel with sharp objects or it may make a dent in the panel resulting abnormal operation of the HMI Maintenance and inspection Do not touch the internal parts of the HMI or it may cause electric shock or product damage...

Page 2: ... 154 08 x 85 92 mm CPU ARM Cortex A8 800 MHz Flash ROM 256 Mbytes RAM 256 Mbytes Non volatile memory 32 Kbytes Touch panel 4 wire resistive touchscreen 10 000 000 operated Buzzer Multi tone frequency 2 to 4 kHz 80 dB Network interface N A 10 100 Mbps auto detection built in isolated power circuit Note 2 Serial communication port RS422 RS485 Note 2 N A Memory card SD SDHC USB 1 USB client Ver 2 0 E...

Page 3: ... düşerek çarpmasını önlemek için kancaya sırtının üzerine asın Cihaz enerjili iken kabloları değiştirmeyiniz Bu elektrik çarpmasına veya personel yaralanmasına neden olabilir Operatör paneli ekranına keskin objeler ile dokunmayınız aksi takdirde operatör panelinin anormal şekilde çalışmasına neden olabilir Bakım ve İnceleme Operatör panelinin iç donanım veya parçalarına kesinlikle dokunmayın aksi ...

Page 4: ... Ç özünürlük 800 x 480 Piksel Aydınlatma LED Aydınlatma Yarım ömürde 25o C de 20 000 saatten az 1 Ekran Ö lçüsü 154 08 x 85 92 mm CPU ARM Cortex A8 800 MHz Flash ROM 256 Mbytes RAM 256 Mbytes Kalıcı olmayan Hafıza 32 Kbytes Dokunmatik 4 wire resistive touchscreen 10 000 000 dokunma Buzzer Multi tone frequency 2 to 4 kHz 80 dB Ethernet Arabirimi Yok 10 100 Mbps oto tespit İzolasyonlu Not 2 Seri Hab...

Page 5: ...拔出電線的動作 請重新檢查連接電線再啟動 通訊電路的配線 採用正確的接地迴路 以避免通訊不良 為防止較大的雜訊干擾造成人機介面無法正常運作 請用單獨的配線槽將人機介面的通訊電纜和所有電 源線及馬達動力線分開 3 型號說明 1 DOP 2 1 3 07 4 HS 5 4 6 6 7 5 8 ZM 1 產品名稱 DOP Delta Operation Panel HMI 2 系列名 1 100 系列人機 3 尺寸 07 7 0 4 型別 Type HE Ethernet HS standard 5 顯示規格 4 WVGA 6 外部裝置 代碼 手搖輪 SD 15 Keys 21 Keys 2 6 7 7 出線長度 5 5 公尺 A 10 公尺 8 線材 ZM ZD D SUB 接頭 4 各部位說明 DOP 107HE42x DOP 107HE46x DOP 107HS42x DOP 107HS4...

Page 6: ...acklight 常溫 25 C 下半衰期 2 萬小時 Note 1 顯示範圍 154 08 x 85 92 mm 中央處理器 ARM Cortex A8 800 MHz Flash ROM 256 Mbytes RAM 256 Mbytes 斷電保持記憶體 32 Kbytes 觸控面板 四線電阻式 10 000 000 operated 蜂鳴器 Multi Tone Frequency 2 4 kHz 80 dB 網路介面 N A 10 100 Mbps 自動偵測 內建隔離電路 Note 2 串列通訊埠 RS422 RS485 Note 2 N A 記憶卡 SD SDHC USB 1 USB Client Ver 2 0 緊急停止按鈕 B 接點 x 2 A 接點 x 1 B 接點 x 1 額定電壓 DC 30V 最大額定電流 1A 最小適用負載 DC 5V 1 mA 適用規格 IEC60...

Page 7: ...拔出电线的动作 请重新检查连接电线再启动 通讯电路的配线 采用正确的接地回路 以避免通讯不良 为防止较大的噪声干扰造成人机界面无法正常运作 请用单独的配线槽将人机界面的通讯电缆和所有电 源线及马达动力线分开 3 型号说明 1 DOP 2 1 3 07 4 HS 5 4 6 6 7 5 8 ZM 1 产品名称 DOP Delta Operation Panel HMI 2 系列名 1 100 系列人机 3 尺寸 07 7 0 4 型别 Type HE Ethernet HS standard 5 显示规格 4 WVGA 6 外部装置 代码 手摇轮 SD 15 Keys 21 Keys 2 6 7 7 出线长度 5 5 公尺 A 10 公尺 8 线材 ZM ZD D SUB 接头 4 各部位说明 DOP 107HE42x DOP 107HE46x DOP 107HS42x DOP 107HS4...

Page 8: ...acklight 常温 25 C 下半衰期 2 万小时 Note 1 显示范围 154 08 x 85 92 mm 中央处理器 ARM Cortex A8 800 MHz Flash ROM 256 Mbytes RAM 256 Mbytes 断电保持内存 32 Kbytes 触控面板 四线电阻式 10 000 000 operated 蜂鸣器 Multi Tone Frequency 2 4 kHz 80 dB 网络接口 N A 10 100 Mbps 自动侦测 内建隔离电路 Note 2 串行通讯端口 RS422 RS485 Note 2 N A 记忆卡 SD SDHC USB 1 USB Client Ver 2 0 紧急停止按钮 B 接点 x 2 A 接点 x 1 B 接点 x 1 额定电压 DC 30V 最大额定电流 1A 最小适用负载 DC 5V 1 mA 适用规格 IEC60...

Reviews: