![Delta AH10EN-5A Series Operation Manual Download Page 80](http://html1.mh-extra.com/html/delta/ah10en-5a-series/ah10en-5a-series_operation-manual_2471620080.webp)
E t h er N et / I P O p er a ti o n Ma n u a l
7 - 2
_7
This section will provide an overview of how to use EtherNet/IP to connect to a Delta EtherNet/IP Adapter via the 3rd party
software. Here we take Rockwell’s Software Studio 5000 as an example.
7.1
Architecture
RA EIP Scanner use Ethernet to connect a Delta Adapter; as for the PC, it can connect to the RA Scanner via the
Ethernet/USB.
※
Rockwell Software Studio 5000, ControlLogix, RSLogix are registered trademarks of Rockwell Automation, Inc.
7.2
Create a New Project
Open the Studio 5000 and click the “New Project” under the “Create” section.
Select a PLC. Take 1756-L71 as an example here.
New Project
Select PLC