89
│
www.deltaww.com
User Manual
A9000
AC Power Source
:END
Set(query) stop frequency for each sequence
:DEGRee
Set(query) start phase angle for each sequence
PULSE
:VOLTage
:AC
Set(query) PULSE AC voltage
:FREQuency
Set(query) PULSE frequency
:SPHase
Set(query) start phase angle of AC voltage of PULSE
:COUNt
Set(query) how many times to execute PULSE
:DCYCle
Set(query) output duration of PULSE waveform,
cannot be longer than total period
:PERiod
Set(query) total period
STEP
:VOLTage
:AC
Set(query) start voltage for STEP mode
:DVOLtage
:AC
Set (query) voltage change for each step at STEP mode
:FREQuency
Set (query) start frequency at STEP mode
:DFRequency
Set (query) frequency change for each step at STEP mode
:SPHase
Set (query) start phase angle at STEP mode
:DWELl
Set (query) output duration for each step at STEP mode
:COUNt
Set (query) how many steps for STEP mode
SYNThesis
Set (query) which synthesis waveform to use.
There
are
:AMPLitude
Set (query) harmonic voltage amplitude for each order
:PHASe
Set (query) harmonic phase angle for each order
TRIG
Set Trig events for PULSE, LIST, STEP mode
Following are functions, examples and returned parameters for SOURCE command
:
[SOURce:]CURRent:LIMit
Function
:
Set (query) total current limit Irms
。
Example
:
[SOURce:]CURRent:LIMit?
[SOURce:]CURRent:LIMit 25.5