1 Safety Precautions

 WARNING!

This mark indicates procedures which, if improperly performed, might lead to 
the death or serious injury of the user.

 CAUTION!

This mark indicates procedures which, if improperly performed, might possibly 
result in personal harm to the user, or damage to property.

 WARNING !

Installation should be left to the dealer or another professional. Improper installation may cause water 
leakage, electrical shock, or fire. 

Install the air conditioner according to the instructions given in this manual. Incomplete installation may 
cause water leakage, electrical shock, or fire. 

Be sure to use the supplied or specified installation parts. Use of other parts may cause the unit to 
come to lose, water leakage, electrical shock, or fire. 

Install the air conditioner on a solid base that can support the weight of the unit. An inadequate base or 
incomplete installation may cause injury in the event the unit falls off the base. 

Electrical work should be carried out in accordance with the installation manual and the national 
electrical wiring rules or code of practice.  Insufficient capacity or incomplete electrical work may cause 
electrical shock or fire. 

Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. 

For wiring, use a cable length enough to cover the entire distance with no connection. Do not use an 
extension cord. Do not put other loads on the power supply, use a dedicated power circuit. (Failure to 
do so may cause abnormal heat, electric shock or fire.) 

Use the specified types of wires for electrical connections between the indoor and outdoor units. 
Firmly clamp the interconnecting wires so their terminals receive no external stresses.  Incomplete 
connections or clamping may cause terminal overheating or fire. 

After connecting interconnecting and supply wiring be sure to shape the cables so that they do not 
put undue force on the electrical covers or panels. Install covers over the wires.  Incomplete cover 
installation may cause terminal overheating, electrical shock, or fire. 

If any refrigerant has leaked out during the installation work, ventilate the room. (The refrigerant 
produces a toxic gas if exposed to flames.) 

After all installation is complete, check to make sure that no refrigerant is leaking out. (The refrigerant 
produces a toxic gas if exposed to flames.) 

Summary of Contents for 80SF040J24

Page 1: ...www delta dct com VRF FLOOR STANDING INDOOR UNITS 80SF SERIES INSTRUCTION MANUAL WARNING Read and follow all safety precautions in Instruction Manual improper use can cause serious injury...

Page 2: ......

Page 3: ...nstallation Location 7 3 3 Electrical Requirement 9 4 Installation Instruction 10 4 1 Installation of the Connection Pipe 10 4 2 Installation and Test of Drain Pipe 10 5 Introduction of DIP Switch 12...

Page 4: ...of practice Insufficient capacity or incomplete electrical work may cause electrical shock or fire Be sure to use a dedicated power circuit Never use a power supply shared by another appliance For wi...

Page 5: ...be sucked in when the compressor is run causing abnormal pressure in the freezer cycle which will lead to breakage and even injury Be sure to establish an earth Do not earth the unit to a utility pipe...

Page 6: ...ght Mode ON OFF Fig 1 No Part Name No Part Name Air outlet Air inlet Control panel Drain pipe Wirless controller box Signal receiver Panel 2 2 Nominal Operating Condition Item Indoor Condition Outdoor...

Page 7: ...der by pressing this key COOL it indicates the cooling status DRY it indicates the dehumidifying status and the fan runs at the low speed FAN it indicates the fan status HEAT it indicates the heating...

Page 8: ...here are two options Air On and Air Off reserved SLEEP There are two options Sleep On and Sleep Off TURBO There are two options Turbo On and Turbo Off SET There are two options Set Temperature On and...

Page 9: ...ed with or without wired controller When 88 LED displays E6 and the wired control is in normal status it indicates the unit is the control of the wired controller rather than the buttons on the contro...

Page 10: ...and service agent 1 A place with heat source steam and inflammable gas 2 A place with high frequency facility such as radio equipment electric welder or medical equipments 3 A seaside saline alkali p...

Page 11: ...a swimming pool 11 A location from which the condensation water can be drained out conveniently 3 2 3 Dimensions Data and Installation Space Requirements Dimensions Data 80SF040J24 80SF060J24 Unit mm...

Page 12: ...deal with on time by the inconvenience of the business contact It should be guide under the professional personnel when the air conditioner unit is moved to other place 3 3 Electrical Requirement 1 El...

Page 13: ...2 1 Precautions When Doing the Piping Work 1 Keep piping as short as possible and slope it downwards at a gradient of at least 1 100 so that air may not remain trapped inside the pipe 2 Keep pipe siz...

Page 14: ...inter connecting wire in the same direction as the piping 6 Install the Baffle after installation of connection pipe and drainage pipe according to Fig 4 Screws Hole Baffle Fig 10 1 Loosen the screws...

Page 15: ...ed on the mainboard of indoor unit If wired controller is used make sure to set the address of wired controller to the position same as the address code on corresponding indoor unit The address of wir...

Page 16: ...ctory set and sealed so that it is not allowed to be modified by the user Below is factory default setting The default setting of the capacity DIP switch as shown above is related to the maximum capac...

Page 17: ...aker in accordance with the related laws and regulations and electric company standards CAUTION The power source capacity must be the sum of the air conditioner current and the current of other electr...

Page 18: ...ng hole of the chassis Please connect the power connection cord with the breaker If the power cord is not long enough please prolong it with terminal block Power connection cord BN BU YEGN To breaker...

Page 19: ...ect the lowest programmable temperature 1 Trial operation in cooling mode may be disabled depending on the room temperature Use the remote controller for trial operation as described below 2 After tri...

Page 20: ...unit stops running 2 Use soft cloth when cleaning cabinet If the unit is very dirty dip cloth into warm water below 40 C and dry the cloth before cleaning it 3 Don t spray water on indoor unit as spra...

Page 21: ...set temperature is too high The heating effect is not good The air filter screen is dirty or is clogged The door or window is not closed fully The set temperature is too low The remote controller is...

Page 22: ...0 Heating Capacity kw Btuh Air Flow Rate m h CFM 1600 942 1700 1000 Sound Level dB A 45 48 Input of Motor kW 0 27 0 31 Power Supply Anti electric Shock Protect Unit Dimensions W D H P k Di i W D H 208...

Page 23: ......

Page 24: ...Thank you for Choosing airconditioners Perfectly engineered for your comfort www delta dct com...

Reviews: