MACRO CPU Board Hardware Reference Manual
12
Jumper and Switch Configurations
Switch Configurations
SW1: MACRO Slave Node Configure
SW1 Setting # of Servo Channels
and Nodes Used
MACRO Servo
Nodes Specified
Station
Channel Nos.
Station Channel
Starting Addresses
0 (default) 4
0, 1, 4, 5
1, 2, 3, 4
$C000, $C008, $C010, $C018*
1
4
8, 9, 12, 13
1, 2, 3, 4
$C000, $C008, $C010, $C018*
2
2
0, 1
1, 2
$C000, $C008*
3
2
4, 5
3, 4
$C010, $C018*
4
2
8, 9
1, 2
$C000, $C008*
5
2
12, 13
3, 4
$C010, $C018*
6
6
0, 1, 4, 5, 8, 9
1, 2, 3, 4, 5, 6
$C000, $C008, $C010, $C018,
$C020, $C028*
7
8
0, 1, 4, 5, 8, 9, 12,
13
1, 2, 3, 4, 5, 6, 7,
8
$C000, $C008, $C010, $C018,
$C020, $C028, $C030, $C038*
8
2
0, 1
9, 10
$C090, $C098
9
2
4, 5
9, 10
$C090, $C098
10
2
8, 9
9, 10
$C090, $C098
11
2
12. 13
9, 10
$C090, $C098
12
6
0, 1, 4, 5, 8, 9
1, 2, 3, 4, 9, 10
$C000, $C008, $C010, $C018,*
$C090, $C098
13 0
(I/O
only) None None
None
14
(Reserved For Future Use)
15 ***
0
11
-
-
* These addresses are for stack axis boards. Add $40 to these addresses for backplane axis boards.
** Other bits of this I-variable may also be set to enable I/O nodes or other slave stations it is commanding
*** A setting of 15 forces the station to use its factory default I-variables on power-up/reset.
SW1
Setting
First Axis
Board Servo IC
Second Axis
Board Servo IC
PMAC2’s I996 Value
** (Turbo PMAC2’S
I6840, etc.
PMAC2’s I1000, I1002
Value (Turbo PMAC2’s
I70, I71, etc.)
0 (default)
4-axis
None
$F8033
$0033
1 4-axis None
$FB300
$3300
2 4-axis None
$F8003
$0003
3 4-axis None
$F8030
$0030
4 4-axis None
$F8300
$0300
5 4-axis None
$FB000
$3000
6 4-axis 4-axis
$F8333
$0333
7 4-axis 4-axis
$FB333
$3333
8 2-axis None
$F8003
$0003
9 2-axis None
$F8030
$0030
10 2-axis
None
$F8300
$0300
11 2-axis
None
$FB000
$3000
12 4-axis 2-axis
$FB333
$0333
13 None
None
$F8000
$0000
14
(Reserved For Future Use)
15*** -
-
$F8800
-
* These addresses are for stack axis boards. Add $40 to these addresses for backplane axis boards.
** Other bits of this I-variable may also be set to enable I/O nodes or other slave stations it is commanding
*** A setting of 15 forces the station to use its factory default I-variables on power-up/reset.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com