© 2017 Delta-T Devices Ltd
Page
8
DL6
◼
Up to 6 SM150Ts can connect to a DL6 logger but only one of
the integrated temperature sensors can be connected.
◼
Each is wired as a differential, powered sensor.
These details illustrate connection to channel 6 and 7:
SM150T wiring
Colour
DL6 terminal
Power 0V
brown
0V
Power V+
white
V+
Signal HI
blue
IN+
Signal LO
black
IN-
Tempe
grey
RES IN+
Cable shield
green
◼
In
DeltaLINK
configure channel 1 - 6 as Moisture Probe
SM150T
and channel 7
as
SM150T Temperature
.
See also the
DL6 Quick Start Guide
and the
DeltaLINK
onlin Help.
* Download the latest version (v3.6 or later) of the DeltaLINK logger software from
Softaware and Manuals DVD.
DL2e
◼
Up to 30 SM150Ts may be connected (or 60 if not
reading the temperature).
◼
Each soil moisture sensor is connected as a differential,
powered sensor.
This example uses channels 57 and 58 with a LAC1 input
card configured in 15-channel mode, and warm-up channel 63.
SM150T wiring
Colour DL2e terminal
Power 0V
brown
CH62- or 61-
Power V+
white
CH63 NO
Signal HI
blue
CH58+
Signal LO
black
CH58-
Cable shield
green
CH61- or 62-
Tempe
grey
CH57+ and CH57-
◼
Configure the DL2e logger channels by selecting the appropriate
SM150T
sensor
types from the LS2Win sensor library. Use Ls2Win version 1.0 SR10 or later*.
See also the
DL2e
User Manual
or
LS2Win Help
.
* Download the latest version of Ls2Win logger PC software from
from our
Software and Manuals DVD.