![Delta Regis DRTQ Series User Manual Download Page 12](http://html1.mh-extra.com/html/delta-regis/drtq-series/drtq-series_user-manual_2478479012.webp)
DRTQ Series Manual
12
Date:10/01/2009 Time:20:29:13 Unit S/N:
123456 Transducer: 25 In Lb
Job:TOOL123 #1
Measurement direction: CW
Maximum Torque Limit: 10.75 In Lb
Minimum Torque Limit: 10.25 In Lb
Threshold Torque Limit: 5.00 In Lb
Peak Time: 0.500 Seconds
Maximum recorded: 10.69 In Lb
Minimum recorded: 10.50 In Lb
Sigma: 0.068
Cp: 1.234
Cpk: 0.908
Readings above maximum: 0
Readings below minimum: 0
Percentage not OK: 0.000%
Reading # Peak
1 10.64
2 10.50
3 10.53
4 10.54
5 10.55
6 10.52
7 10.51
8 10.53
9 10.65
10 10.69
Exporting Data from Peak Mode (USB)
Note:
Before exporting any data you must install
the USB Device Driver. Refer to the USB
installation instructions of this manual.
1. To export your data select the
[Export]
button.
2. You will be given the option of creating a
name for your data. You may select letters
and numbers to create the name. To switch
between the numeric and alpha screens
press the
[123]
button when it is on the alpha
screen or press the
[ABC]
button when it is
on the numeric screen. To move on select
the
[Next]
arrow.
3. You will now have the option of exporting it to
an SD card or a USB Cable. Refer to Figure
12.1 to view the export screen.
4. From the measurement export screen select
the data you would like to export, and press
the
[USB]
or
[SD Card]
buttons.
Exporting Data from Peak Mode Continued
1. The Data that is exported from your computer
will display the following information in the
HyperTerminal program. Please refer to Figure
12.2 to view what the data export will look like.
2. Users may copy and paste the data read out in
HyperTerminal into a Microsoft Office application
Exporting Data
Fig. 12.1
Fig. 12.2
(1)
5.24
(2)
5.25
(3)
5.42
(4)
5.25
(5)
5.28
(6)
5.25
(7)
5.34
(8)
5.30