![Delta Regis DRTQ Series User Manual Download Page 11](http://html1.mh-extra.com/html/delta-regis/drtq-series/drtq-series_user-manual_2478479011.webp)
DRTQ Series Manual
11
Using Peak Mode
4. You may begin testing your tool. For screwdrivers
and power tools, insert the rundown fixture into the
transducer before you begin.
a. You can press the statistics button in the lower
right hand corner to access additional
information.
b. You can export the captured readings by
pressing the save button in the lower right
hand corner.
5. Once the export button is pressed the
[Export
Name]
(Job Name) screen will appear. It is
recommended to save the export name as the
serial number of the tool(s) for easy reference.
Press
[Next]
to proceed to the next screen.
6. Once you have captured your peak you
may save and export your data to a
computer via a USB Cable or an SD card,
or you may clear the reading by selecting
[clear]
Using Track Mode
1. Select
[Track]
and select the
[Next]
arrow.
2. Select the units you are measuring from the menu and
select the
[Next]
arrow.
3. The screen for the Track mode will now appear, please
see Figure 11.4 for an example. The High and Low
Torque limits will be displayed from their settings in Peak
mode.
4. When you have finished measuring in Track mode you
may return to the main menu by selecting the
[Main
Menu]
arrow.
Measuring Torque
Fig. 11.1
Fig. 11.2
Fig. 11.4
Fig. 11.3
(1)
5.24
(2)
5.25
(3)
5.42
(4)
5.25
(5)
5.28
(6)
5.25
(7)
5.34
(8)
5.30