DRTQ Series Torque Tester
User Manual
Delta Regis Tools, Inc.
6945 NW LTC Parkway
Port St. Lucie, FL 34986
[email protected]
www.deltaregis.com
Page 1: ...DRTQ Series Torque Tester User Manual Delta Regis Tools Inc 6945 NW LTC Parkway Port St Lucie FL 34986 sales deltaregis com www deltaregis com...
Page 2: ...atures and Settings 7 9 Display Screen 7 Main Menu 7 Settings 7 Adjusting Your Settings 8 9 Measuring Torque 10 11 Using Quick Run 10 Using Measure Mode 10 Peak Mode 11 Track Mode 11 Exporting Data 12...
Page 3: ...eds the maximum torque value Doing so may result in damage to the unit and injury to the operator Unauthorized personnel should never be permitted to operate this unit Never use additional accessories...
Page 4: ...ance analysis Export data directly to computer through USB or save to SD Card Automatic screen rotation level sensor flips screen vertically or horizontally Quick Run mode provides the ability to quic...
Page 5: ...DRTQ Series Manual 5 Component Identification LCD Touch Screen Rundown Fixture Not available on all units Docking Plate Optional Accessory Power On Button AC Power Adapter SD Card Slot USB Port...
Page 6: ...pability for a centered process is a statistical value that is used to indicate how closely a series of test samples are grouped around the target value Torque Threshold The Torque Threshold is the mi...
Page 7: ...t Settings The DRTQ series torque tester offers a settings menu that allow users to adjust the features on the unit to their own specifications The following step by step instructions will help you na...
Page 8: ...ure automatically shuts down the torque tester when it is not in use in order to conserve battery life Users are allowed to adjust the set amount of time the torque tester is on before the Sleep Mode...
Page 9: ...etected the value of peak time will set the maximum time allotted to detect a new peak If a new peak is not achieved within that time the last peak value will be locked in and displayed To adjust the...
Page 10: ...to graph the Peak Time 5 To Adjust the length of time on the graph please refer to Adjusting Your Settings Peak Time Using Measure Mode 1 Select Measure Mode from the main menu 2 Peak or Track if you...
Page 11: ...eference Press Next to proceed to the next screen 6 Once you have captured your peak you may save and export your data to a computer via a USB Cable or an SD card or you may clear the reading by selec...
Page 12: ...he option of creating a name for your data You may select letters and numbers to create the name To switch between the numeric and alpha screens press the 123 button when it is on the alpha screen or...
Page 13: ...from your DRTQ torque tester to the USB port on your computer 2 Once it is connected a Found New Hardware bubble will appear over your task bar on the computer s desktop screen 3 Next the Hardware wiz...
Page 14: ...ic location Advanced option and click Next 6 Browse to where the fascdc inf file is located and click Next 7 The wizard will begin the installation of the driver A box will pop up with a warning that...
Page 15: ...ew Hardware Wizard has finished installing the software Click Finish 9 The virtual serial port has been installed The determine the port name click on Start then Control Panel then double click on Sys...
Page 16: ...DRTQ Series Manual 16 10 Select the Hardware tab and click on Device Manager 11 The Device Manager Program will appear Expand the Ports group In this case the port is COM23 USB Driver Installation...
Page 17: ...ter USBtoSer Install USB VID_03EB PID_6119 USBtoSer Install include mdmcpq inf CopyFiles FakeModemCopyFileSection AddReg USBtoSer AddReg USBtoSer AddReg HKR DevLoader ntkern HKR NTMPDriver usbser sys...
Page 18: ...in for calibration Unit turns off by itself Low Battery Recharge the unit Sleep mode time set too short Adjust sleep mode time Unit will not turn on Low Battery Recharge the unit Flash memory corrupt...
Page 19: ...Inc may charge Purchaser at prevailing prices Repair parts are warranted by Delta Regis Canada Inc for a period of one 1 year from the date of delivery provided however that repairs or replacements t...