18
Counter Interface Operation
1. Display Interface Schematic View
1. NORMAL indicator: Shows indication
under normal mode
2. SET indicator: Indication under setting
mode
3. COUNTER indicator: Indication under
counter mode
4. CPU power-off memory function
2. Key Function
SET: Function switch key
OK: Confirmation selection key
UP: Lifting key
DOWN: Lowering key
3. Operation Function Description
After connecting to the power for the first time, the system enters into the total count state, and
LED display screen is lit up and displays 0000 (system default total count is 0000), and LED
indicator NORMAL is lit up. At this time, if the machine starts operation, counting starts, and
the total count range is 0~9999. Once it reaches the maximum value of 9999, it then starts to
count from zero again, and counting cycle repeats in such manner. When the machine stops the
operation or operates again after power-off, the previous count value is memorized.
1. SET key function description
1-1. Under the standby or operation state,
press the SET key the first time
, the system
enters into the count quantity setting, and LED display screen flashes.
Press the SET
key the first time, the system enters into the total quantity (ten thousandth digit,
thousandth digit) setting
, LED display screen flashes, and the LED indicator SET is
lit up, followed by pressing UP or DN key to adjust the count quantity (system default
count value is 00, and the setting range is 00 ~ 99). After 3S without pressing any keys
or other key is pressed within 3S, the system confirms the setting is complete and a
buzzer is sounded as an indication of the completion.
Under the standby or operation state,
press the SET key the second time, the system
enters into the total count quantity (hundredth digit, tenth digit, single digit)
setting
, LED display screen flashes
, and the LED indicator SET is lit up,
followed by pressing UP or DN key to adjust the count quantity (system default count
value is 000, and the setting range is 000 ~ 999). After 3S without pressing any keys or
other key is pressed within 3S, the system confirms the setting is complete and a
buzzer is sounded as an indication of the completion.
1-2. Under the standby or operation state,
press the SET key the third time, the system
enters alarm count quantity (thousandth digit, hundredth digit) setting
, LED
display screen flashes
, and the LED indicator SET is lit up, followed by