![Delta Regis DRFF-208 Operation And Setup Manual Download Page 13](http://html1.mh-extra.com/html/delta-regis/drff-208/drff-208_operation-and-setup-manual_2478482013.webp)
DRFF-208R / DRFF-512R / DRFF-519R Screw Feeder
Operation and Setup Manual
www.deltaregis.com
13
12
Infrared Sensor
Voltage
Enters diagnostic mode and displays the DC
voltage of the infrared sensors ~0470 when open,
~5000 when screw present
(Program Value: 00: disable; 01 enable)
13
Screw
Specification
Set according to the thickness of the screw head
(Program Value: 00: Large Screw; 01: Small Screw)
NOTE:
1. Vibration motor shutdown delay value must never exceed brush motor
shutdown delay value in order to prevent screws from jamming at the screw
head guide plate.
2. When Program 12 is enabled, the vibration and drum/brush motors will
not run. The turntable will rotate at minimum speed for several cycles before
stopping. Once the turntable has stopped, adjust the infrared sensors to
display ~2500 for optimal sensing. After the adjustment has been made, turn
the machine off then on to continue using the machine. Screws with a small
headed may require a value greater than 2500.
3. Program 13 is set based on the thickness of the screw head. If the screw
head is 0.5mm or less, use 01. If the screw head is greater than 0.5mm, use 00.
Error Codes
Error Code
Description
E-01
Drum/Brush motor seized
E-02
Turntable motor seized
E-03
Drum/Brush motor not detected
E-04
Vibration motor not detected
E-05
Drum/Brush and Vibration motor not communicating