Revision 2016/03, 6ELE, V1.14
4-57
Group 5: Multi-step speeds parameters
05.00
1st Step Speed Frequency
Unit: 0.01
05.01
2nd Step Speed Frequency
Unit: 0.01
05.02
3rd Step Speed Frequency
Unit: 0.01
05.03
4th Step Speed Frequency
Unit: 0.01
05.04
5th Step Speed Frequency
Unit: 0.01
05.05
6th Step Speed Frequency
Unit: 0.01
05.06
7th Step Speed Frequency
Unit: 0.01
05.07
8th Step Speed Frequency
Unit: 0.01
05.08
9th Step Speed Frequency
Unit: 0.01
05.09
10th Step Speed Frequency
Unit: 0.01
05.10
11th Step Speed Frequency
Unit: 0.01
05.11
12th Step Speed Frequency
Unit: 0.01
05.12
13th Step Speed Frequency
Unit: 0.01
05.13
14th Step Speed Frequency
Unit: 0.01
05.14
15th Step Speed Frequency
Unit: 0.01
Settings
0.00 to
599
.0Hz
Factory Setting: 0.00
The Multi-function Input Terminals (refer to Pr.04.05 to 04.08) are used to select one of the AC motor drive
Multi-step speeds. The speeds (frequencies) are determined by Pr.05.00 to 05.14 as shown in the following.
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
05.00
05.01
05.02
05.03
05.04
05.05
05.06
05.07
05.08
05.09
05.10
05.11
05.12
05.13
05.14
01.15
OFF
OFF
OFF
OFF
OFF
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
M
u
lt
i-
fu
n
c
ti
o
n
te
rm
in
a
ls
0
4
.0
5
~
0
4
.0
8
Frequency
Master Speed
JOG Freq.
2nd speed
(
2)
MI3 to MI6
1st speed
(
to MI6 1)
MI3
Jog Freq.
Multi-speed via External Terminals
Run/Stop
PU/external terminals
/communication
3rd speed
(
3)
MI3 to MI6
4th speed
(
4)
MI3 to MI6