DeviceNet Remote I/O Communication Module RTU-DNET
DVP-PLC Application Manual
7
OFF
When DeviceNet is off, the I/O data in
the buffer area will be cleared.
IN0
ON
When DeviceNet is off, the I/O data in
the buffer area will be held.
IN1 Reserved
Note:
z
Please set up the function switch when the power is switched off. After the setup is completed, re-power
RTU-DNET.
z
When RTU-DNET is operating, changing the setting of the function switch will be invalid.
z
Use slotted screwdriver to adjust the DIP switch carefully in case you scratch the switch.
2.7 Extension Port
The extension port is used on connecting RTU-DNET to DVP Slim DI/DO extension units and special modules.
3 Basic
Operation
3.1 Connecting RTU-DNET to DVP Slim DI/DO Extension Unit
z
Open the fixing clips on top and bottom of RTU-DNET. Meet the extension port of Slim DI/DO with RTU-DNET.
z
Press the fixing clips on top and bottm of Slim DI/DO and check if the connection is fine.
R
T
U
-D
N
E
T
D
V
P
-1
6
S
P
D
V
P
-0
2
D
A
R
T
U
-D
N
E
T
D
V
P
-1
6
S
P
D
V
P
-0
2
D
A
3.2 Installing RTU-DNET and DVP Slim DI/DO on DIN Rail
z
Use 35mm DIN rail.
z
Open the DIN rail clip on RTU-DNET and Slim DI/DO. Insert RTU-DNET and Slim DI/DO onto the DIN rail.
z
Clip up the DIN rail clips on RTU-DNET and Slim DI/DO to fix them on the DIN rail, as shown below.
R
T
U
-D
N
E
T
D
V
P
-1
6
S
P
D
V
P
-0
2
D
A
35mm DIN rail