In addition to the modes mentioned above, there are three special modes in
BX6.3_AC100. These are passive modes, they will be enabled automatically
under special condition.
BX6.3_AC100 changes to standalone mode automatically during a power
outage occur. At this time, grid side is disconnected and home load are
supported by battery power as much as possible.
BX6.3_AC100 can be micro-grid under this mode, to provide simulated grid for
load and PV inverter.
• Standalone mode
4.1.6 Special Modes
Figure 4-12 : Standalone mode current flows
Figure 4-13 : Standalone mode behavior
19:00
12:00
07:00
00:00
24:00
PV power
PV power used
for home load consumption
Excess PV power
Battery discharges
Home load power usage
Solar Panel
Grid
HXA
Distribution Panel
Production
Charge or discharge
Consumption
BX6.3_EX100 / BX6.3_AC100
CT
Home Load
Disconnected with grid
Standalone mode
Model
Max charge / discharge load crrent
13 A
BX6.3_AC100
19.6 A
BX12.6_AC100
47
Startup