EN
18
19
8/ Remove one or several associations
9/ Obstacle detection
> 3s
CR 2430
x 2
The motors of the TYMOOV range include the obstacle detection feature.
After locking on an obstacle, the motor reverses direction by about 15 cm.
Obstacles can only be detected when the stops have been set.
Obstacle detection sensitivity settings
If an inadvertent obstacle is detected, you can reduce the detector’s sensitivity to
the obstacle.
To return to the original confi guration (so that the motor has no associated
transmitter):
To carry out a factory reset, the remote control must be associated to one motor
only.
> 3s
CR 2430
x 2
10/ Factory reset
Press button B on the front
panel of the remote control,
until the LED fl ashes green.
On the transmitter, press and
hold the
button for
more than 3 seconds until the
LED turns on.
The motor will be
activated briefl y:
Once = high sensitivity
Twice = low sensitivity
Repeat the operations above to switch between modes.
Press button B on the front
panel of the remote control
twice
, until the LED fl ashes
orange.
Press and hold the
button for more than 3 seconds
until the red LED comes on.
8.1 Remove the remote control association with the
motor
- Remove the front panel of the remote control.
- Press button A.
The LED will fl ash red.
- Press
as many times as required to select the motor (receiver) to remove.
- Press the
button.
The motor will be activated briefl y
- Press button A to exit.
8.2 Remove all associations
- Remove the front panel of the remote control.
- Press button A.
The LED will fl ash red.
- Press the
and
buttons at the same time and hold for 3 seconds.
The motor will be activated briefl y
- Press button A to exit.
All the associated motors will be removed.
CR 2430
The motor is briefl y
activated twice.
Then the motor is activated
once. It means it is in
association waiting.
The motor will now have no
associations or settings