34
35
EN
6/ ASSOCIATING A ROOM THERMOSTAT WITH
A TECHNICAL UNIT
(1)
Output number
1 to 16 depending on the system.
Transmitter type
0
Underfloor heating
1 Heater
Heating percentage
limitation
From 10 to 100% in 10 increments (100%= No
limitation, by default).
6.2 WITH A PROGRAMMABLE ROOM
THERMOSTAT (PRT)
❶
Turn the selector knob to
.
❷
Press and hold the 2nd button from the left for 3 seconds.
Release.
❸
The screen displays
Ln01
. Press OK to open the
association mode.
❹
The screen displays
CF20
. Press OK to open the setting,
then press + and - to select the output with which the
thermostat is to be associated.
Confirm with OK.
❺
The screen displays
CF21
. Select the transmitter and
press OK.
❻
The screen displays
CF22.
Select the limitation value and press OK to confirm.
To exit the current mode, press or turn the dial.
3 s
(1)
CF20: a product associated with an output also controls the following outputs in the same
manner, if these are not associated.
7/ CONFIGURING THE TECHNICAL UNIT
5 s
3 s
7.1 WITH A ROOM THERMOSTAT (RT)
❶
From the OFF mode, press and hold the 2nd button
from the left for 5 seconds.
Release.
❷
Press and hold
OK
for 3 seconds. Release.
❸
The screen displays
CL01
.
• Press + or - to select the parameter to be set
(CL01 to CL08).
• Press OK to open the setting mode, then + and - to
perform the setting.
❹
Confirm with OK.