1/ Location
2/ Connection
Since the temperature measurement sensor is inside the box, you must install the
thermostat flush-mounting box:
- on an accessible wall at a height of 1.50 m
- away from heat sources (fireplaces, sunlight) and draughts (windows, doors)
IMPORTANT:
Do not install the thermostat on a wall in contact with the outdoors
or with an unheated room (e.g. garage, etc.) The sleeve output in the flush-
mounting box must be blanked off (with mastic) in order to avoid unwanted air
movements that could bias the sensor reading.
2A max. / 230V~
TYBOX 5000
2A max. / 230V~
N
L
2A max. / 230V~
Circulator
The diagrams provided are simplified for greater clarity. Protections and other
accessories required by standards are not illustrated. - Standard NF C15-100
and good practice must be complied with. Connected or nearby units must not
generate excessive interference (directive 89/336/EEC).