Delta Controls
Access Door Module
Page 5 of 26
UL
S
TANDARDS
C
OMPLIANCE
This system has been tested by Underwriters Laboratories, Inc. for UL Indoor requirements per Standard UL
294, Access Control System Units. It has been tested for compliance with Listed Proximity Card Reader
Sentinel-Prox SR-2400 only.
The only configuration evaluated by UL is a system containing one ASM-24E, one ADM-2W704, an UL
Listed Transformer Basic Electric Industrial Cat. No. 7511 CBDH, ENC761 enclosure, and Applied Wireless
Listed Proximity Card Reader, Sentinel-Prox SR-2400. The system employs Wiegand 26 communication
protocol and was verified in the evaluation.
UL has not evaluated the following features of the ADM-2W704 and therefore should not to be connected in
UL applications: Battery Backup, Auxiliary Power, Request to Exit, or Auxiliary Relay Outputs. Any items not
evaluated by UL shall not be connected to the system in UL applications or installations.
All Read Ranges specified in this Manual are nominal and are dependent upon environmental and credential
electrical parameters and have not been evaluated by UL.
Product has been evaluated for the following levels in accordance with UL294 6
th
Edition:
•
Destructive Attack – Level I
•
Line Security – Level I
•
Endurance – Level IV
•
Standby Power – Level I
•
Battery capacity for loss of primary power 0 hours